10
Regeneration Day Override Setting (the factory default is 0)
1) Press the SET button. The screen will show the Regeneration
Day Override in blinking numbers.
2) To change the number, use the UP or DOWN arrows.
3) Press the SET button.
Salt Amount Setting
1) Press the SET button. The screen will show the Salt Amount
as pounds in blinking numbers.
2)
DO NOT CHANGE THE NUMBER
.
3) Press the SET button.
Softening Capacity Setting
1) Press the SET button. The screen will show the Capacity as
grains in blinking numbers.
2)
DO NOT CHANGE THE NUMBER
.
3) Press the SET button.
Hardness Setting (the factory default is 10)
1) Press the SET button. The screen will show the Hardness as
grains per gallon in blinking numbers.
2) To change the number, use the UP or DOWN arrows.
3)
Press the SET button.
If water was tested by Master Water Conditioning, follow
recommendations on water analysis, for hardness setting.
NOTE: If water was not tested by Master Water, multiply the
hardness in (gpg) reading you have by two ( 2 ). This is done
because when raising the pH, hardness will increase.
Final Check:
1. Fill the brine tank with Solar Salt and the Res-Up Feeders with
Res-Up (one quart is provided).
2. Make sure the drain line connection meets all plumbing codes
and that the drain line size can handle the backwash flow rate of
the softener.
3. Make sure the Inlet and Outlet on bypass valve are open.
4. Make sure the control valve timer is plugged into an electrical
outlet with power 24 hours per day.
5. Check all piping for leaks.