8
Filling Combination Unit with Water:
Figure 4
1. Push the FOR REGENERATION button
(Figure 4)
on the
controller down for 5 seconds. This will initiate a manual
regeneration. You will notice a flashing hour glass during
regeneration.
The controller will indicate that the motor is turning the camshaft
to cycle C1 (BACKWASH). The controller will indicate the total
regeneration time remaining. Filling tank in this position allows air
to escape from drain.
Open the bypass inlet valve ¼ turn and allow water to flow into the
mineral tank at a slow rate.
Warning: IF WATER ENTERS THE TANK TOO FAST, ALL THE
RESIN WILL BE FLUSHED TO DRAIN DURING START UP.
2. When water is running steadily at the drain, open the bypass
valve’s inlet and outlet to their maximum position.
3. Simultaneously press the SET and UP buttons on the controller
for 1 second then release, the motor will advance the cam to C2.
Once C2 is displayed simultaneously press the SET and UP
buttons on the controller for 1 second then release, the motor will
advance the cam to C3. Repeat this procedure until the timer
enters the C7 (FAST RINSE) position. The softener will go
through the rinsing cycle and then automatically advance to
(BRINE REFILL) C8 and fill the brine tank with the proper amount
of water.
4. The control valve will advance to C0 (REGENERATION
COMPLETE) and Time of Day will be displayed. This is
treated water.