Installation and Operation Manual 

 

MP-NS-30T/40T 

with the 

268/762 Logix Control Valve 

MASTER

Water Conditioning Corp.

www.masterwater.com

 
 
 
                                             

April 2006 

Summary of Contents for MP-NS-30T

Page 1: ...Installation and Operation Manual MP NS 30T 40T with the 268 762 Logix Control Valve MASTER Water Conditioning Corp www masterwater com April 2006 ...

Page 2: ...Valve Electrical Connection Instructions on Logix 762 Electrical Connection 8 Filling Combination Unit with Water Details for Filling Combination Unit Tank with Water 9 Filling Combination Unit with Water Continued Details for Filling Combination Unit Tank with Water Continued Logix 762 Control Valve Timer Settings Setting the Timer 10 Logix 762 Control Valve Timer Settings Continued Setting the T...

Page 3: ...kwash flow control and bypass with 1 copper or pvc connection Calcite CF Boxes NS Mix CF Boxes System Description The combination unit has a Logix top mounted automatic control valve with an impulse meter to initiate regeneration The Logix Valve is constructed of non corrosive Noryl material and is rated at a maximum working water pressure of 100 psi It uses a 762 microprocessor based timer in con...

Page 4: ...he factory 2 Center the distributor and make sure it is resting on the bottom of the tank The top of the distributor pipe will extend above the top of the tank this was prefitted at the factory 3 Cover the top opening of the distributor pipe before filling the tank with media Model Calcite NS Mix NS 30 40T cubic foot 1 2 cubic foot 4 Pour all filter media provided with the unit into the top of the...

Page 5: ... Place gasket into nut and secure 1 copper or pvc tail piece with a nut Repeat the procedure for the outlet connection DO NOT OVERTIGHTEN THE NUT Figure 2 2 The control valve s drain connection is 3 4 npt and is located on the back of the control valve 3 Turn the control valve upside down and ensure that the control valve distributor o rings are in place Use silicone lubricant on the o rings 4 Pla...

Page 6: ...ule 80 PVC is used make sure to follow the proper primer and solvent instructions 3 The drain line connection is located on the back of the valve as you face the timer It is recommended you install a union on the drain line for servicing The drain line must be of adequate size to allow for full regeneration flow Figure 3 The control valve drain connection is 3 4 npt Never decrease the drain piping...

Page 7: ...oners must be installed after the well tank or water meter if its public water supply Master Water Conditioner Brine tank Air Gap Drain Overflow fitting to floor drain gravity Treated water Untreated to outside 224 Shoemaker Rd Pottstown PA 19464 Typical Piping Layout ...

Page 8: ...lectrical service provides power 24 hours per day We recommend installing a surge protector to protect unit from power surges which are not covered by warranty Brine Tank 1 The brine tank should be located directly beside the Combination Unit mineral tank 2 Connect the 3 8 poly tubing to the 3 8 white elbow compression fitting located on the right side of the Logix control valve See Figure Below T...

Page 9: ... already installed at the factory 1 Remove plastic control valve cover by spreading sides while lifting 2 Plug transformer into back of timer following existing wires 3 Plug transformer into a properly grounded 120V 60 HZ electrical outlet 4 The screen will now change between the Gallons Remaining to Regeneration and the current Gallons per Minute gpm flow rate ...

Page 10: ...ALL THE RESIN WILL BE FLUSHED TO DRAIN DURING START UP 2 When water is running steadily at the drain open the bypass valve s inlet and outlet to their maximum position 3 Simultaneously press the SET and UP buttons on the controller for 1 second then release the motor will advance the cam to C2 Once C2 is displayed simultaneously press the SET and UP buttons on the controller for 1 second then rele...

Page 11: ...ing numbers 2 To change the Time of Day use the UP or DOWN arrows 3 Press the SET button Day of Week Setting 1 Press the SET button The screen will show the Day of Week in blinking triangle 2 To change the Day of Week use the UP or DOWN arrows 3 Press the SET button Time of Regeneration Setting the factory default is 2 AM 1 Press the SET button The screen will show the Time of Regeneration in blin...

Page 12: ...w the Hardness as grains per gallon in blinking numbers 2 To change the number use the UP or DOWN arrows 3 Press the SET button If water was tested by Master Water Conditioning follow recommendations on water analysis for hardness setting NOTE If water was not tested by Master Water multiply the hardness in gpg reading you have by two 2 This is done because when raising the pH hardness will increa...

Page 13: ...nual bypass valve Leak at riser pipe seal Insure that riser pipe is properly sealed at o ring seal InMPect pipe for cracks Insufficient brine Check brine float height and clean assembly if necessary Check flow rate capabilities of safety float and air check assembly Plugged injector or injector screen Inspect and clean injector and or injector screen Symptom No Brine Draw Possible Cause Solution P...

Page 14: ...to height of valve Damaged valve disk Replace all valve disks Partially restricted drain line Remove restriction Symptom Insufficient Refill to Brine Tank Possible Cause Solution Brine refill control Remove and clean Restricted flow rate in brine line Check flow rate capabilities of the safety float aircheck assembly Symptom Excessive Water in Brine Tank Possible Cause Solution Plugged drain line ...

Page 15: ...n distributor pipe slots as needed Symptom Salt in Water to Service After Regeneration Possible Cause Solution Injector is too small for system size Install correct injector Brine draw time excessively long due to low water pressure Increase water pressure above 25 psig 172 kPa minimum Restricted drain line Remove drain line restriction Insufficient rinse volume Increase slow rinse time fast rinse...

Page 16: ...14 ...

Page 17: ...15 ...

Page 18: ...16 ...

Page 19: ...17 ...

Page 20: ...ll be void in the event of damages from external sources or where the conditioner has been operated at pressure in excess of 100 pounds per square inch or at a temperature greater than 100 degrees F or less than 32 degrees F Incidental costs or consequential damages are not covered by this warranty All defective parts shall be returned prepaid to Master Water Conditioning Corporation for inspectio...