Installation and Operating Instructions for  

 268/742 Logix 

Top Mount Combination Unit  

 
Model #:
 

 

____  FES-30T   ____ FES-40T Iron Filter and Softener 
____  NS-30T    ____ NS-40T   pH Control and Softener 
____  TS-30T 

____ TS-40T   Dechlorination and Softener 

 
 
Shipping Carton Description  / unit:
 

 

# of 

cartons 

Contents 

Description 

Mineral tank 

Distributor pipe installed 

Brine tank 

464 shutoff valve assembly.  *

NOTE:

 

268/742  Logix valved is shipped in 
brine tank. 

268/742 
 Logix control 
valve 

268/742 timer and backwash flow 
control and bypass with 1” copper or 
pvc connection 

 

Birm for FES 

½ CF Boxes 

 

Calcite for NS 

½ CF Boxes 

 

NS-Mix for NS 

½ CF Boxes 

 

Carbon for TS 

½ CF Boxes 

 
System Description: 

 

The combination unit has a Logix top mounted automatic control 
valve with an electronic timer to initiate regeneration.  The  Logix 
Valve is constructed of non-corrosive Noryl

 material and is rated at 

a maximum working water pressure of 100 psi. It uses a 742 
microprocessor based timer to actuate regeneration in the following 
ways: 

a. Manual regeneration button to start an emergency 

regeneration 

b. Regeneration day setting 

 

 

Summary of Contents for FES-30T

Page 1: ...d Operation Manual 30 40 COMBINATION UNITS with the 268 742 Logix Control Valve MASTER Water Conditioning Corp Water Conditioning Corp Water Conditioning Corp Water Conditioning Corp www masterwater c...

Page 2: ...ion Instructions on Logix 742 Electrical Connection Filling Combination Unit with Water Details for Filling Tank with Water 8 Filling Combination Unit with Water Continued Details for Filling Tank wit...

Page 3: ...268 742 Logix control valve 268 742 timer and backwash flow control and bypass with 1 copper or pvc connection Birm for FES CF Boxes Calcite for NS CF Boxes NS Mix for NS CF Boxes Carbon for TS CF Bo...

Page 4: ...ributor and make sure it is resting on the bottom of the tank The top of the distributor pipe will extend above the top of the tank this was prefitted at the factory 3 Cover the top opening of the dis...

Page 5: ...Place gasket into nut and secure 1 copper or pvc tail piece with a nut Repeat the procedure for the outlet connection DO NOT OVERTIGHTEN THE NUT Figure 2 2 The control valve s drain connection is 3 4...

Page 6: ...le 80 PVC is used make sure to follow the proper primer and solvent instructions 3 The drain line connection is located on the back of the valve as you face the timer It is recommended you install a u...

Page 7: ...ners must be installed after the well tank or water meter if its public water supply Master Water Conditioner Brine tank Air Gap Drain Overflow fitting to floor drain gravity Treated water Untreated t...

Page 8: ...ectrical service provides power 24 hours per day We recommend installing a surge protector to protect unit from power surges which are not covered by warranty Brine Tank 1 The brine tank should be loc...

Page 9: ...outlet 4 The screen will now display 268 then the Time of Day Filling Combination Unit with Water Figure 4 1 Push the FOR REGENERATION button Figure 4 on the controller down for 5 seconds This will in...

Page 10: ...n the controller for 1 second then release the motor will advance the cam to C3 Repeat this procedure until the timer enters the C7 FAST RINSE position The softener will go through the rinsing cycle a...

Page 11: ...he SET button Regeneration Frequency Setting the factory default is 7 1 Press the SET button The screen will show the Regeneration frequency in blinking numbers 2 To change the number use the UP or DO...

Page 12: ...ith Solar Salt and the Res Up Feeders with Res Up one quart is provided 2 Make sure the drain line connection meets all plumbing codes and that the drain line size can handle the backwash flow rate of...

Page 13: ...er pipe seal Insure that riser pipe is properly sealed at o ring seal InMPect pipe for cracks Insufficient brine Check brine float height and clean assembly if necessary Check flow rate capabilities o...

Page 14: ...o height of valve Damaged valve disk Replace all valve disks Partially restricted drain line Remove restriction Symptom Insufficient Refill to Brine Tank Possible Cause Solution Brine refill control R...

Page 15: ...eded Symptom Salt in Water to Service After Regeneration Possible Cause Solution Injector is too small for system size Install correct injector Brine draw time excessively long due to low water pressu...

Page 16: ...14...

Page 17: ...15...

Page 18: ...16...

Page 19: ...17...

Page 20: ...l be void in the event of damages from external sources or where the conditioner has been operated at pressure in excess of 100 pounds per square inch or at a temperature greater than 100 degrees F or...

Reviews: