background image

30

DO NOT DIVE.

SPECIFICATIONS

Swim Spa  
Dimensions

Electrical 
Required

Water  
Capacity  
(gallons)

Weight  
Dry/Full (lbs.)

Number 
of Pumps

Jet  
Count

Trainer 12

144"x 94"x 51" 240V, 50 Amp

1,300

1,620 / 12,410

2

55

Trainer 14

174"x 94"x 51" 240V, 50 Amp

1,425

2,260 / 14,130

2

55

Trainer 17

201"x 94"x 51" 240V, 50 Amp

1,925

2,700 / 18,735

2

45

Trainer 18

215"x 94"x 60" 240V, 50 Amp

2,500

3,240 / 22,400

2

44

Trainer 19

231"x 94"x 51" 240V, 30/50 Amp

2,040

2,460 / 19,392

4

48

Summary of Contents for Trainer 12

Page 1: ...W A T E R T O T H E E X T R E M E swimming l fitness l therapy l family fun l premium line of jetted swim spas WATER TO THE EXTREME byMasterSpas OWNER S MANUAL...

Page 2: ......

Page 3: ...tes or for other information please visit www masterspas com and follow the links to the customer service section Record Of Ownership Name Address City ________________________________________________...

Page 4: ...oting Guide 25 Why Chemicals are Important 26 Maintenance Recommendations 27 28 Winterizing Your Swim Spa 29 Swim Spa Specifications 30 Optional Exercise Equipment 31 Main Menus 32 Fill It Up 33 Swim...

Page 5: ...ern The sign should be mounted with screws or another type of permanent fastener Additional or replacement signs can be obtained from your dealer or direct from the factory INTRODUCTION It s time to r...

Page 6: ...o connect a minimum 6 AWG 13 302mm2 solid copper conductor between this unit and any metal equipment metal enclosures of electrical equipment metal water pipe or conduit within 5 feet 1 5m of the unit...

Page 7: ...n cannot use this swim spa unless they are supervised at all times DANGER Risk of Injury The suction fittings in this swim spa are sized to match the specific water flow created by the pump Should the...

Page 8: ...a f Persons using medication should consult a physician before using a swim spa since some medication may induce drowsiness while other medication may affect heart rate blood pressure and circulation...

Page 9: ...uthorized entry and injuries WARNING People with infections sores or the like should not use the swim spa Warm and hot water temperatures may allow the growth of infectious bacteria if not properly di...

Page 10: ...ded in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying this equipment At least two lugs marked Bonding Lugs are provided on the e...

Page 11: ...TILISER UNE CUVE DE RELAXATION WARNING TO AVOID INJURY EXERCISE CARE WHEN ENTERING OR EXITING THE SWIM SPA OR HOT TUB AVERTISSEMENT POUR VITER DES BLESSURES USER DE PRUDENCE EN ENTRANT DANS UNE CUVE D...

Page 12: ...CORDANCE WITH MANUFACTURER S INSTRUCTION ATTENTION LA TENEUR DE L EAU EN MATI RES DISSOUTES DOIT TRE CONFORME AUX DIRECTIVES DU FABRICANT Hyperthermia occurs when the internal temperature of the body...

Page 13: ...osed position as air bubbles tend to cool the water 4 TOPSIDE CONTROL PANEL You may safely control all functions from inside or outside your swim spa using the Topside Control Panel This Panel is used...

Page 14: ...safety and are located on the interior walls of your swim spa The on off switch is located on the topside control panel 12 EQUIPMENT CONTROL SYSTEM This houses the wiring and electrical components ne...

Page 15: ...ximum jet action The water flow may be directed to different areas of the swim spa depending on the position of the diverter controls 16 SECONDARY PUMP This pump produces water flow through the stand...

Page 16: ...240 VAC only The only electrical supply for your swim spa must include a 50 AMP switch or circuit breaker to open all non grounded supply conductors to comply with section 422 20 of the National Elec...

Page 17: ...electrical service using 6 AWG copper wire with 8 AWG ground wire should be ran to the Spa Control Pack in the swim spa This electrical supply should have an external GFCI installed See electrical ho...

Page 18: ...damage results from improper wiring ON OFF ON OFF ON OFF ON OFF ON OFF 50 50 50 TEST 50 1 2 3 4 5 WHITE NEUTRAL BLACK HOT RED HOT GREEN GROUND Instruments Balboa Incorporated Wire Key House Breaker Bo...

Page 19: ...pment remains above grade and is not subject to flooding The equipment side s of the swim spa must be accessible in the event that future service is need ed In the event that service is required your...

Page 20: ...r and are ready to operate It may be necessary in some instances to bleed air from the jet pumps in your swim spa if after the priming mode the swim spa pumps run but do not move water the pump may ha...

Page 21: ...sium monoperoxysulfate or potassium monopersulfate to burn off the chloramines or bromamines A non chlorine shock acts by releasing oxygen in the water which serves the same function as chlorine The a...

Page 22: ...face cleaners high pH or algeacides as well as other organic materials Low levels of calcium or sanitizer can also cause foaming Also double rinse your bathing suits as they will hold residual soap af...

Page 23: ...he regular filter cartridge with a filter cleaner every 30 days and rinse the Eco Pur cartridge with a hose to remove any buildup of containments Do not soak the Eco Pur cartridge in filter cleaner If...

Page 24: ...g granules sodium Dichlor s triazinetreone on initial start up to begin sanitizing the swim spa water Always refer to the chemical manufactures dosage recommendations listed on the container It is imp...

Page 25: ...EVERY 180 DAYS Drain and refill your swim spa with fresh water install a new Eco Pur filter element clean the regular filter and repeat start up procedure The regular filter should be replaced at lea...

Page 26: ...is less forgiving then a pool and requires that whatever is put into it have a pH as close to neutral as possible That is why only chemicals made for swim spas or spas should be used Always refer to...

Page 27: ...eria or algae growth Adjust sanitizer if necessary Cloudy Water Dirty filters or inadequate filtration Clean filters and adjust filtration times Water chemistry not balanced Adjust chemistry levels Su...

Page 28: ...oudy water and possible corrosion of plumbing and fittings may also occur 2 Heat Heat causes much quicker evaporation and also will cause minerals and metals to precipitate out of solution 3 Air Dust...

Page 29: ...erage with normal swim spa use With heavy use they will need to be cleaned more often The filter elements are one of the most important components of your swim spa Not only are they essential for clea...

Page 30: ...internal Jet insert with a pair of needle nose pliers Clean plastic filter at the back of the Jet insert so all holes are free of debris Reinstall Jet insert and outer ring NOTE To prevent premature f...

Page 31: ...where applicable 6 Using your shop vac in a blowing mode insert the hose into the nozzle of each jet and blow the trapped water from the lines into the interior of the swim spa 7 After this is complet...

Page 32: ...Pumps Jet Count Trainer 12 144 x 94 x 51 240V 50 Amp 1 300 1 620 12 410 2 55 Trainer 14 174 x 94 x 51 240V 50 Amp 1 425 2 260 14 130 2 55 Trainer 17 201 x 94 x 51 240V 50 Amp 1 925 2 700 18 735 2 45 T...

Page 33: ...ips are located along the sides of your swim spa next to the grab rails that are placed around the perimeter of the swim area An optional exercise book is available through your dealer that will show...

Page 34: ...Temperature while the numbers are flashing in the LCD Pressing the LIGHT button while the numbers are flashing will enter the menus The menus can be exited with certain button presses Simply waiting f...

Page 35: ...n if you have a 2nd pump to turn it on The pumps will now be running in high speed to facilitate priming If the pumps have not primed after 2 minutes and water is not flowing from the jets in the swim...

Page 36: ...y programmed with two filter cycles that will run 10 minutes after power up The filter duration is programmable See page 7 At the start of each filter cycle Pump 2 if there is one will run briefly to...

Page 37: ...h Pressing the button again will cause the temperature to change in one direction e g UP After allowing the display to stop flashing pressing the Temperature Button will cause the temperature to flash...

Page 38: ...de See Page 4 under Pumps for other circulation modes If the swim spa is configured for 24HR circulation the heater pump runs continuously Since the heater pump is always running the swim spa will mai...

Page 39: ...t to the same duration Sets Filter length in hours SET FLTR12 While the Temperature is still flashing press Light repeatedly until FLTR appears in the LCD SET RANGE Main Screen READY RANGE FLTR12 Main...

Page 40: ...p will run by itself when Priming Mode is exited WATER TEMPERATURE IS UNKNOWN After the pump has been running for 1 minute the temperature will be displayed TOO COLD FREEZE PROTECTION A potential free...

Page 41: ...ted Checks below HEATER IS DRY There is not enough water in the heater to start it The swim spa is shut down After the prob lem has been resolved you must press any button to reset and restart heater...

Page 42: ...Sensor Balance is poor fault has been established for at least 1 hour Call for Service SENSOR FAILURE SENSOR A SENSOR B A temperature sensor or sensor circuit has failed Call for Service 29 DO NOT DI...

Page 43: ...ars after the system has been running normally for a period of time MEMORY FAILURE CLOCK ERROR Contact your dealer or service organization CONFIGURATION ERROR SWIM SPA WILL NOT START UP Contact your d...

Page 44: ...via the 3 5mm connector inside the locker door CAUTION Risk of Electric Shock Do not leave compartment door open CAUTION Risk of Electric Shock Replace components only with identical components and Do...

Page 45: ...cated by a blue LED When the unit is in the standby position the red LED will be lit Remote Synchronizing Press and hold MODE button on the remote The display will then show pair Keep pressing this ke...

Page 46: ...canning Press once toggle mute Press and hold toggle mute Press once seek up Press and hold change to manual scanning Press once Volume DOWN a value Press and hold Fast volume down Press once Volume U...

Page 47: ...to the swim spa but no closer then 5 feet If the swim spa does not respond contact your local service company PUMP S DO NOT OPERATE 1 Press the Jets button on your control panel If you hear the pumps...

Page 48: ...the control panel for heat light indicator If the light is on and not blinking the swim spa should be heating Wait a reasonable amount of time approximately 1 hour to see if the water temperature is r...

Page 49: ...t to turn or not turn at all Remove the handle from the top of diverter valve by gently prying up on both sides of the handle assembly at the same time Turn the cap piece counter clockwise It may be n...

Page 50: ...et requires only peri odic cleaning with a stream of water from a garden hose FILTER CLEANING NOTE Never operate the swim spa without the filters installed Damage to the pumps and other components cou...

Page 51: ...AND MAINTENANCE RECORD DATE Drain Clean Swim Spa Clean Filter Cartridge Test GFCI Soak Filter Cartridge in Solution Clean and Condition Swim Spa Cover Miscellaneous Service Miscellaneous Service DATE...

Page 52: ...AND MAINTENANCE RECORD DATE Drain Clean Swim Spa Clean Filter Cartridge Test GFCI Soak Filter Cartridge in Solution Clean and Condition Swim Spa Cover Miscellaneous Service Miscellaneous Service DATE...

Page 53: ...AND MAINTENANCE RECORD DATE Drain Clean Swim Spa Clean Filter Cartridge Test GFCI Soak Filter Cartridge in Solution Clean and Condition Swim Spa Cover Miscellaneous Service Miscellaneous Service DATE...

Page 54: ...AND MAINTENANCE RECORD DATE Drain Clean Swim Spa Clean Filter Cartridge Test GFCI Soak Filter Cartridge in Solution Clean and Condition Swim Spa Cover Miscellaneous Service Miscellaneous Service DATE...

Page 55: ......

Page 56: ...POP10H2XOM Rev 201707 6927 Lincoln Parkway Fort Wayne Indiana 46804 800 860 7727 www masterspas com WATER TO THE EXTREME byMasterSpas...

Reviews: