background image

24

DO NOT DIVE.

24

For eco Pur

 Water Filter system

Step 1: 

  

Your spa should be filled using a Pre-filter, which can be obtained from your local  
dealer. This Pre-filter will help remove many of the minerals existing in the water, 
which will make adjusting the water balance easier after a new fill. Never use more 
then 50% softened water when filling the spa.

Step 2: 

 

  During the initial filling of the spa, add a sequestering agent to combat suspended 
minerals in the water. The agents are sold under many different names such as Mineral 
Clear, Stain and Scale, Metal Protect, and other brands. Allow water to circulate and  
filter for at least 12 hours before adding any other chemicals. 

Step 3:

  

Test water for pH, total Alkalinity, and Calcium hardness. The pH should be 7.2 - 7.8 
and the total Alkalinity 80-150 PPM. Calcium hardness levels should be maintained 
between 150 and 250 PPM (part per million).

Step 4: 

  

Adjust pH and total Alkalinity (TA) utilizing the directions on the chemical bottles.  
Wait 15 minutes, test and adjust if necessary.

Step 5: 

  

It may be necessary to retest and add additional chemicals to get to the proper levels  
in Step 3.

Step 6:

   

Add 2 ounces of concentrated chlorinating granules

*

 (sodium Dichlor-s-triazinetreone) 

on initial start up to begin sanitizing the spa water. Always refer to the chemical manu-
factures dosage recommendations listed on the container. It is important not to add 
the chlorinating granules until the pH, alkalinity and calcium hardness have been  
adjusted to their proper levels.

*sPeCIaL NOte:

We recommend a minimum level of 1.0 ppm residual chlorine be maintained in spa water. Always refer to the 
chemical manufacturer’s dosage recommendations listed on the container.  
When adding chlorine or non-chlorine shock/oxidizer always broadcast across the water while the pumps are 
running. 
The quantities of sanitizer and oxidizer shown in this manual are for 500 gallon spas and may have to be adjust-
ed depending on the actual amount of water that your spa holds. See the specifications section of this manual 
for the correct gallons of your spa.  
The concentration of active ingredients in spa chemicals varies by manufacturer. The amounts of sanitizer sug-
gested in this manual are based on spa chemicals that have the active ingredient percentages listed below:

Chlorine 

 

Non-Chlorine Shock/ Oxidizer

Active ingredient: 

 

Active ingredient:

Sodium dichlor ................................. 99% 

Potassium peroxymonosulfate ....................... 42.8%

Other ingredients ................................ 1% 

Inert ingredients ............................................ 57.2%

Total ............................................... 100% 

Total............................................................ 100% 

WATER QUALITY MAINTENANCE START-UP

DO NOT DIVE.

Summary of Contents for LEGEND LSX700

Page 1: ...MICHAEL PHELPS LEGEND SERIES OWNERS MANUAL...

Page 2: ......

Page 3: ...t without prior notice To check on updates or for other informa tion please visit www masterspas com and follow the links to the customer service section Record Of Ownership Name Address City ________...

Page 4: ...Guide 27 Why Chemicals are Important in a Spa 28 Maintenance Recommendations 29 30 Winterizing Your Spa 31 Spa Specifications 32 LSX Series Main Menu Screen 33 34 Spa and Shortcut Screen 35 Settings S...

Page 5: ...e sign should be mounted with screws or another type of permanent fastener Additional or replacement signs can be obtained from your dealer or direct from the factory INTRODUCTION It s time to relax Y...

Page 6: ...o connect a minimum 6 AWG 13 302mm2 solid copper conductor between this unit and any metal equipment metal enclosures of electrical equipment metal water pipe or conduit within 5 feet 1 5m of the unit...

Page 7: ...re that children can not use this spa unless they are supervised at all times DANGER Risk of Injury The suction fittings in this spa are sized to match the spe cific water flow created by the pump Sho...

Page 8: ...spa f Persons using medication should consult a physician before using a spa since some medication may induce drowsiness while other medication may affect heart rate blood pressure and circulation Fo...

Page 9: ...y and injuries WARNING People with infections sores or the like should not use the spa Warm and hot water temperatures may allow the growth of infectious bacteria if not properly disinfected CAUTION S...

Page 10: ...rovided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying this equipment At least two lugs marked Bonding Lugs are provided on t...

Page 11: ...TILISER UNE CUVE DE RELAXATION WARNING TO AVOID INJURY EXERCISE CARE WHEN ENTERING OR EXITING THE SPA OR HOT TUB AVERTISSEMENT POUR VITER DES BLESSURES USER DE PRUDENCE EN ENTRANT DANS UNE CUVE DE REL...

Page 12: ...CORDANCE WITH MANUFACTURER S INSTRUCTION ATTENTION LA TENEUR DE L EAU EN MATI RES DISSOUTES DOIT TRE CONFORME AUX DIRECTIVES DU FABRICANT Hyperthermia occurs when the internal temperature of the body...

Page 13: ...rought into the spa as they will cause the diverter to seize up It is best to turn the diverter valve only when the pump is turned off Your new Master Spa features a variety of jet styles All jets reg...

Page 14: ...s by opening or closing the air control valves Typically one dial controls the air to water ratio and mix to one group of jets When not in use the air controls should be kept in the closed position as...

Page 15: ...uired 12 DRAINING YOUR SPA The drain is located behind a removable corner panel This panel is on the right side of the spa as you are facing the topside control panel You can access the drain by unscr...

Page 16: ...varies by model Should the high limit switch trip repeatedly contact your dealer or qualified service representative to diagnose the problem 17 SLICE VALVES These valves are used by service personnel...

Page 17: ...r flow neces sary to actuate the ozone generator This fractional HP pump runs for 24 hours of efficient filtration and heating This pump is standard on all LSX Series spas 21 PUMP UNION These are used...

Page 18: ...equipment pack to allow connection to local ground points The ground wire must be at least 8 AWG copper wire and must be con nected securely to a grounded metal structure such as a cold water pipe All...

Page 19: ...eutral wire is not required between the G F C I and the system box GRN GRN GROUND RED HOT BLK HOT BLK HOT RED HOT RED HOT WHT NEUTRAL WHT WHT BLK HOT GRN GROUND TB1 IDF00007 mac 6 17 97 Actual wiring...

Page 20: ...to confirm that your surface is adequate for sup porting a spa Be sure to locate your spa so that equipment remains above grade and is not subject to flooding The equipment side s of the spa must be a...

Page 21: ...has 2 unions and the heater has 2 unions A newly delivered spa may have loose unions caused in transporting the spa Check that all slice valves are open in the up position The slice valves may become...

Page 22: ...lling a spa This is not a service covered under warranty To relieve and airlock loosen the union on the discharge of the pump see arrow on picture of pump below Water should leak out Tighten the union...

Page 23: ...or acrylic eye skin irritation rapid chlorine or bromine loss and total alkalinity destruction With high pH the results can be cloudy water eye skin irritation scale forma tion and poor chlorine or b...

Page 24: ...what happens when you put sugar in coffee or tea 10 Useful life of water in days Water should be drained at least once every 180 days Useful life may vary by usage and bather load 11 Defoamer Foaming...

Page 25: ...dge with a filter cleaner every 30 days and rinse the Eco Pur cartridge with a hose to remove any buildup of containments Do not soak the Eco Pur cartridge in filter cleaner If water appears to be vis...

Page 26: ...ted chlorinating granules sodium Dichlor s triazinetreone on initial start up to begin sanitizing the spa water Always refer to the chemical manu factures dosage recommendations listed on the containe...

Page 27: ...r spa with fresh water install a new Eco Pur filter element clean the regular filter and repeat start up procedure The regular filter should be replaced at least once every year aFter eaCH use Add 1 o...

Page 28: ...es that whatever is put into it have a pH as close to neutral as possible That is why only chemicals made for spas should be used Always refer to the chemical manufactures dosage rec ommendations list...

Page 29: ...ssary Bacteria or algae growth Adjust sanitizer if necessary Cloudy Water Dirty filters or inadequate filtration Clean filters and adjust filtration times Water chemistry not balanced Adjust chemistry...

Page 30: ...r cloudy water and possible corrosion of plumbing and fittings may also occur 2 Heat Heat causes much quicker evaporation and also will cause minerals and metals to precipitate out of solution 3 Air D...

Page 31: ...e they essential for clean water but they also extend the life of the spa equipment Your filter elements should be cleaned on a regular basis once a month on average with normal usage With heavy use t...

Page 32: ...her cleaning materials that are abrasive Chlorine salts sulfides or other rusting metals can also erode this thin coating exposing the metal to corrosion The best defense to combat corrosion on stainl...

Page 33: ...ing water out of your unit 3 Remove access panels from equipment area 4 Loosen all pump unions 5 Remove winterizing plug from face of the pump s where applicable 6 Using your shop vac in a blowing mod...

Page 34: ...mensions Electrical Requirements Water Capacity gallons Weight Dry Full lbs Number of Pumps Jet Count LSX 700 84 x 84 x 38 240V 50 Amp 335 785 3 732 4 62 LSX 800 94 x 94 x 38 240V 50 Amp 415 835 4 280...

Page 35: ...ted and the screen will change to show more detailed controls or programming functions DO NOT DIVE The Main Screen Water Temperature Messages Desired Temperature Temperature Range Pump and Heat Menus...

Page 36: ...Set Temperature can then be adjusted with the up and down buttons Pressing the Select button or the Right Arrow button will save the new set temperature On the right side of the screen the menu selec...

Page 37: ...is select ed it can be controlled using the center Select Button Some devices like pumps may have more than one ON state so the icon will change to reflect the state that the equipment is in Below are...

Page 38: ...ight go to another level in the menu PRESS AND HOLD If an Up or Down button is pressed and held when an item in a Menu List is highlighted the list can be scrolled quickly from top to bottom The scrol...

Page 39: ...nerally runs continuously Since the heater pump is always running the spa will maintain set temperature and heat as needed in Ready Mode without polling In Rest Mode the spa will only heat to set temp...

Page 40: ...select the other pumps to turn them on The pumps should be running in high speed to facilitate priming If the pumps have not primed after 2 minutes and water is not flowing from the jets in the spa d...

Page 41: ...art of each filter cycle the pumps will run briefly to purge the plumbing to maintain good water quality On spas equipped with 24 hour circulation systems the filter cycles cannot be set See adjusting...

Page 42: ...12 24 Hour segments Use the Up and Down Buttons to make changes SAVING SETTINGS The Time of Day screen is a simple editable screen that illustrates a feature of the control that applies to all other...

Page 43: ...start time and a duration Each setting can be adjusted in 15 minute increments The panel calculates the end time and displays it automatically FILTER CYCLE 2 OPTIONAL FILTRATION Filter Cycle 2 is OFF...

Page 44: ...tside the hot tub SPECIFIC BUTTONS FOR SPECIFIC DEVICES The panel has dedicated function buttons installed pressing those buttons will activate the device indicated for that button These dedicated but...

Page 45: ...are still active Locking the Settings allows Jets and other features to be used but the Set Temperature and other programmed settings cannot be adjusted Settings Lock allows access to a reduced select...

Page 46: ...ld Mode will last for 1 hour unless the mode is exited manually If spa service will require more than an hour it may be best to simply shut down power to the spa UTILITIES The Utilities Menu contains...

Page 47: ...rature between Fahrenheit and Celsius Time Display Change the clock between 12 hr and 24 hr display Cleanup Cleanup Cycle Duration default is 30 minutes The duration can be set in 30 minute increments...

Page 48: ...number for the System System Model Displays the Model Number of the System Current Setup Displays the currently selected Configuration Setup Number Configuration Signature Displays the checksum for th...

Page 49: ...running for 1 minute the temperature will be displayed POSSIBLE FREEZING CONDITION A potential freeze condition has been detected All pumps are activated In some cases pumps may turn on and off and th...

Page 50: ...tart up See Flow Related Checks below THE HEATER IS DRY There is not enough water in the heater to start it The spa is shut down After the problem has been resolved you must clear the message to resta...

Page 51: ...NSOR A FAULT SENOR B FAULT A temperature sensor or sensor circuit has failed Call for Service COMMUNICATIONS ERROR The control panel is not receiving communication from the System Call for Service TES...

Page 52: ...r up THE CLOCK HAS FAILED Contact your dealer or service organization CONFIGURATION ERROR SPA WILL NOT START UP Contact your dealer or service organization A PUMP MAY BE STUCK ON Water may be overheat...

Page 53: ...ED When the unit is in the standby position the red LED will be lit Remote Synchronizing Press and hold MODE button on the remote The display will then show pair Keep pressing this key Then press the...

Page 54: ...scanning Press once toggle mute Press and hold toggle mute Press once seek up Press and hold change to manual scanning Press once Volume DOWN a value Press and hold Fast volume down Press once Volume...

Page 55: ...the spa does not respond contact your local service company PUMP S DO NOT OPERATE 1 Press the Jets button on your control panel If you hear the pumps trying to operate A Check that all the slice valve...

Page 56: ...ndicator see controls section of manual If the indicator is on the spa should be heating Wait a reasonable amount of time approximately 1 hour to see if the water temperature is changing 6 Check to ma...

Page 57: ...mineral deposits and grit sand that may get into the internal parts of the diverter valve it may become hard to turn or freeze up completely In this case it is necessary to remove the handle and cap o...

Page 58: ...water Attach a garden hose if desired Draining times may vary by model using the external hose bib A sump pump may also be used to drain the spa quickly NOTE When pushing or pulling the assembly in or...

Page 59: ...R AND SPA THIS ALLOWS FOR ADEQUATE VENTILATION OF COVER AND SPA NOTE The cover warranty is provided through the cover manufacturer and not through Master Spas You will need to mail the cover warranty...

Page 60: ...her cleaning materials that are abrasive Chlorine salts sulfides or other rusting metals can also erode this thin coating exposing the metal to corrosion The best defense to combat corrosion on stainl...

Page 61: ...connector plug attached to the end of the uV Lamp and place the upper enclosure assembly in a safe place iv slowly pull the uV Lamp out of the Quartz tube by the white ceramic prong end DO NOT TOUCH...

Page 62: ...n the water removed from the spa and that the uV Lamp and Quartz tube have cooled before performing maintenance on the Quartz tube ii remove the upper enclosure assembly and uV Lamp as described in se...

Page 63: ...the threads on the uV reactor iii screw the compression nut into the threads till it is finger tight do not oVertighten iv after spa is refilled turn the spa on and check the seal around the Quartz t...

Page 64: ...ow you to connect the spa to your phone and home network when installed This accessory Wi Fi module is available thru your dealer This module will need to be connected to the spa control pack located...

Page 65: ...E AND MAINTENANCE RECORD DATE Drain Clean Spa Clean Filter Cartridge Test GFCI Soak Filter Cartridge in Solution Clean and Condition Spa Cover Miscellaneous Service Miscellaneous Service DATE DATE DAT...

Page 66: ...E AND MAINTENANCE RECORD DATE Drain Clean Spa Clean Filter Cartridge Test GFCI Soak Filter Cartridge in Solution Clean and Condition Spa Cover Miscellaneous Service Miscellaneous Service DATE DATE DAT...

Page 67: ......

Page 68: ...POP14MPLSOM Rev 20140903 6927 Lincoln Parkway Fort Wayne IN 46804 260 436 9100 www MasterSpas com FIND US ON...

Reviews: