20
CLEANING AND MAINTENANCE
The equipment must be
disconnected from the
power supply « OFF » and pull
the power plug prior to
performing any maintenance.
Cleaning
Under normal conditions, the water pump is free of
maintenance. However, the pump should not be
placed in the open air during rain, in a humid place,
or dirty or frozen environment.
Freezing, idling or blocking by impurities should
be avoided.
Always disconnect the power supply before
maintenance of the pump.
If the power cable is damaged, it must be
replaced by professional personnel. Damage
caused by short circuiting is not included in scope of
the guarantee.
If trouble with the pump is experienced,
guaranteed repairs must be carried out by an
authorized maintenance center.
Never use solvents such as
petrol, alcohol, ammonia water,
etc. These solvents may damage
the plastic parts.
Cleaning of the built-in filter.
Your pump is equipped with a built-in filter.
Regularly remove the dirt that fixes on the mazes of
the filter.
To clean the filter unit :
Switch off the pump & pull plug from power supply
socket
Unscrew the filter lid from it’s housing
Take out the filter casette and clean it under
running water.
reposition the filter cassette and close the lid
again, plug in the power plug and switch the pump
back on.
Storage
_ If the pump is not going to be used for a long
time or has to be removed for the winter months,
rinse it out with water, empty it completely and
allow it to dry.
_ The equipment must be completely drained
before it is subjected to frost.
_ After long stoppages, make sure the rotor turns
correctly by briefly switching the pump on and off.
TECHNICAL DATA
MPXI1102
Mains voltage / frequency
230V ~ 50Hz
Absorbed power
1100 Watt
Speed
2900 min
-1
Type of protection / Insulation class IP X4
Suction fitting
1"
Delivery fitting
1"
Maximum flow rate
4.600 l/h
Maximum head
45 m
Maximum suction height including load losses
8 m
Power cable
1,2 m
H07RN-F
Maximum dimension of pumped solid particles
3 mm
Maximum admitted working pressure 4,5 bar
Minimum ambient temperature
5° C
Maximum ambient temperature
40° C
Maximum temperature of the pumped fluid 50° C
Maximum number of starts per hour, uniformly
distributed
40
MPXI1102PC
Mains voltage / frequency
230V ~ 50Hz
Absorbed power
1100 Watt
Speed
2900 min
-1
Type of protection / Insulation class IP X4
Suction fitting
1"
Delivery fitting
1"
Maximum flow rate
4.600 l/h
Maximum head
45 m
Maximum suction height including load losses
8 m
Power cable
1,2 m
H07RN-F
Maximum dimension of pumped solid particles
3 mm
Maximum admitted working pressure 4,5 bar
Minimum ambient temperature
5° C
Maximum ambient temperature
40° C
Maximum temperature of the pumped fluid 50° C
Maximum number of starts per hour, uniformly
distributed
40
MPXI1102ALL
Mains voltage / frequency
230V ~ 50Hz
Absorbed power
1100 Watt
Speed
2900 min
-1
Type of protection / Insulation class IP X4
Suction fitting
1"
Delivery fitting
1"
Maximum flow rate
4.600 l/h
Maximum head
45 m
Maximum suction height including load losses
8 m
Power cable
1,2 m
H07RN-F
Maximum dimension of pumped solid particles
3 mm
Maximum admitted working pressure 4,5 bar