18
2 Limitations
BOOSTER SETS MASTER PUMPS are suitable for
domestic use, to pump clean water at constant
pressure; to supply water for domestic use from
wells and cisterns; to supply water for toilets,
washing machines and dish washers and to water
gardens. They can also be used for pressurisation
systems to increase hydrostatic pressure.
WARNING
The pump cannot be used for sea
water and inflammable, corrosive,
explosive or dangerous liquids.
WARNING
Verify that the electropump never
runs without liquids.
TECHNICAL DATA
MPXA08MRCALL
Mains voltage / frequency 220V-240V~50Hz
Absorbed power
800 Watt
No load speed min
-1
2,850
Type of protection / Insulation class
IPX4
Suction fitting
G1"
Delivery fitting
G1"
Maximum flow rate
3.600 l/h
Maximum head
40 m
Maximum suction height including load losses
8 m
Power cable
1,5 m H07 RNF
Weight
13 Kg
Maximum dimension of pumped solid particles
1 mm
Maximum admitted working pressure 1.4-2.4 bar
Minimum ambient temperature
5° C
Maximum ambient temperature
40° C
Maximum temperature of the pumped fluid 35° C
Maximum number of starts per hour, uniformly
distributed
60
Noise emission values measured according to
relevant standard.
Acoustic pressure level
LpA 61 dB(A) K = 3 dB(A)
Acoustic power level
LwA 81 dB(A) K = 3 dB(A)
ATTENTION !
The sound power pressure may
exceed 85 dB(A), in this case
individual hearing protection
must be worn.
MPXA10MRCALL - MPXA10MRCALL/50
Mains voltage / frequency 220V-240V~50Hz
Absorbed power
1100 Watt
No load speed min
-1
2,850
Type of protection / Insulation class
IPX4
Suction fitting
G1"
Delivery fitting
G1"
Maximum flow rate
3.600 l/h
Maximum head
45 m
Maximum suction height including load losses
8 m
Power cable
1,5 m H07 RNF
Weight
18.5 Kg
Maximum dimension of pumped solid particles
1 mm
Maximum admitted working pressure 1.4-2.8 bar
Minimum ambient temperature
5° C
Maximum ambient temperature
40° C
Maximum temperature of the pumped fluid 35° C
Maximum number of starts per hour, uniformly
distributed
60
Noise emission values measured according to
relevant standard.
Acoustic pressure level
LpA 67 dB(A) K = 3 dB(A)
Acoustic power level
LwA 87 dB(A) K = 3 dB(A)
ATTENTION !
The sound power pressure may
exceed 85 dB(A), in this case
individual hearing protection
must be worn.
MPXA10MLALL
Mains voltage / frequency 220V-240V~50Hz
Absorbed power
1100 Watt
No load speed min
-1
2,850
Type of protection / Insulation class
IPX4
Suction fitting
G1"
Delivery fitting
G1"
Maximum flow rate
3.600 l/h
Maximum head
45 m
Maximum suction height including load losses
8 m
Power cable
1,5 m H07 RNF
Weight
23 Kg
Maximum dimension of pumped solid particles
1 mm
Maximum admitted working pressure 1.4-2.4 bar
Minimum ambient temperature
5° C
Maximum ambient temperature
40° C
Maximum temperature of the pumped fluid 35° C
Maximum number of starts per hour, uniformly
distributed
60