Master Plumber 539906 Owner'S Manual Download Page 1

OWNER’S MANUAL

Submersible  
Sump Pumps

Installation/Operation/Parts

For further operating,  

installation, or maintenance assistance: 

Call 800-628-9439

©2012 

TRU526 (09/27/12) 

1569 0195 VERT GEN

1572 0195 Vert GEN

Chicago, IL 60631
Phone: 800-628-9439
www.masterplumberpump.com

539906

539914

540015

540037

540045

Summary of Contents for 539906

Page 1: ...Operation Parts For further operating installation or maintenance assistance Call 800 628 9439 2012 TRU526 09 27 12 1569 0195 VERT GEN 1572 0195 Vert GEN Chicago IL 60631 Phone 800 628 9439 www master...

Page 2: ...r pumps whose discharge line can be shut off or obstructed 10 Personal Safety a Wear safety glasses at all times when working with pumps b Keep work area clean uncluttered and properly lit replace unu...

Page 3: ...m I D e g radiator hose can be connected into discharge line near pump using suitable clamps 6 Install an in line check valve or an in pump check valve to prevent flow backwards through pump when pump...

Page 4: ...will reset automatically and restart motor If protector trips repeatedly pump should be removed and checked as to cause of difficulty Low voltage long extension cords clogged impeller very low head o...

Page 5: ...rtical Float Switch Assembly 1 FPS17 66 FPS17 66 FPS17 66 4 Screw 8 32x7 8 Hex Head 4 U30 951PS U30 951PS 5 Motor 1 6A Volute Upper 1 PS1 31P PS1 31P 6B Volute Upper 1 PS1 24B 7 Screw 8 32x5 8 Phillip...

Page 6: ...ng Float obstructed Restricted intake screen Replace float switch Remove pump and clean pump and piping Remove obstruction Remove the pump and clean the intake screen and the impeller Pump operates bu...

Page 7: ...s been installed to your retail store Contact MASTER PLUMBER Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed...

Page 8: ......

Page 9: ...aci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 800 628 9439 1569 0195 VERT GEN 1572 0195 Vert GEN Chicago IL 60631 Tel fono 800 628 9439 w...

Page 10: ...idad Personal a Use lentes protectores en todo momento cuando trabaje en la bomba b Mantenga el lugar de trabajo limpio despejado y debidamente iluminado guarde todas herramientas y el equipo que no s...

Page 11: ...de manguera de goma de un di metro exterior de 47 6 mm 1 7 8 por ej manguera de radiador a la tuber a de descarga cerca de la bomba utilizando abrazaderas convenientes 6 Instale una v lvula de retenc...

Page 12: ...y revisada para verificar cual es el problema Baja tensi n cables de alargue largos impulsor atascado muy baja altura de aspiraci n o elevaci n o una tuber a de descarga tapada o congelada etc pueden...

Page 13: ...de flotador vertical 1 FPS17 66 FPS17 66 FPS17 66 4 Tornillo cabeza hexagonal 8 32x7 8 4 U30 951PS U30 951PS 5 Motor 1 6A Voluta superior 1 PS1 31P PS1 31P 6B Voluta superior 1 PS1 24B 7 Tornillo cabe...

Page 14: ...so Reemplace el interruptor del flotante desconecta del flotante Descarga obstruida Retire la bomba y limpie la bomba y la tuber a obst culos o hielo en las tuber as El brazo del flotante es Acorte el...

Page 15: ...s cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de MASTER PLUMBER Las bombas cloacales que hayan estado en...

Page 16: ......

Reviews: