INSTALLATION INSTRUCTIONS
Water supply and drainage
CONNECTION TO THE DRINKING WATER SYSTEM
NOTE
If the appliance is replaced, a new water filling hose must be used.
Connect the appliance to a drinking water system using the components provided.
Make sure that the drinking water connection is not bent, crushed or wrapped around
itself.
Connect the cold water supply hose to a 3/4 (inch) threaded connector and make sure it
is tightened correctly.
If the water pipes are new or have not been used for a long period of time, let the water
run to make sure it is clear. This precaution is necessary to avoid the risk of water
blocking or damaging the appliance.
Information on the safety supply pipe
The safety water supply pipe consists of double walls. The hose system guarantees a
preventive intervention by blocking the water flow in case of breakage and when the air
space between the water supply hose itself and the external corrugated hose is full of
water.
IMPORTANT
A hose attached to a sink can burst if installed on the same water line as the dishwasher.
How to connect the safety water supply pipe
1. Pull the safety supply pipes completely out of the storage compartment located
behind the dishwasher.
2. Tighten the screws of the safety supply pipe to the tap with the 3/4-inch thread.
3. Run the water completely before starting the dishwasher.
How to disconnect the safety water supply pipe
1. Turn off the water.
2. Unscrew the safety supply pipe from the tap.
DRAINING CONNECTION
Connect the appliance to a water draining connection so that dirty water from the
washing cycle can drain off.
Connect the draining pipe with a diameter of 4 cm to the siphon drain sleeve.
Make sure that the draining pipe is not bent, crushed or wrapped around itself.
Make sure that there is no plug in the drain that prevents water from draining.
The height of the draining pipe must be less than 1000 mm. The end of the pipe must not
be immersed in water to prevent backflow.