Page 1: ...Installation Operation Manual MI HORIZON3D 55 MI HORIZON3D Digital 3D Cinema System Installation Operation Manual Revision No 1 0 0...

Page 2: ...014 Preliminary Document RJG Changes to software utility PD 0 3 6 th March 2014 Preliminary Document RJG Text Improvement PD 0 4 12 th May 2014 Preliminary Document RJG Packaging additions 1 0 0 22 nd...

Page 3: ...X 323 301 7985 MASTERIMAGE 3D ASIA LLC 22F BYC HIGHCITY B D A 371 17 Gasan dong Geumcheon gu Seoul 153 803 South Korea TEL 82 2 3438 1600 FAX 82 2 3438 1698 MASTERIMAGE 3D EUROPE PLC Pinewood Studios...

Page 4: ...nts of MI HORIZON3D 11 5 Detailed Component Overview 12 5 1 Three Way Beam Optical Head Assembly 12 5 2 Actuator Control Box 13 5 3 Floor Stand 14 5 4 Control Box Front Panel Connections Error Bookmar...

Page 5: ...1 3D Position 30 9 4 2 2D Position 31 9 5 Sync Polarity via the Monitor Application 32 9 6 Setting 3D Position via the Monitor Application 33 9 7 Automation Source via the Monitor Application 34 9 8...

Page 6: ...Installation Operation Manual MI HORIZON3D MASTERIMAGE 3D Inc 6 14 Appendix D Dimensional Drawings 655...

Page 7: ...E high quality 3D eyewear the MI HORIZON3D provides the clearest and truest color 3D picture of any available liquid crystal 3D system This user manual provides all the information required for simple...

Page 8: ...row ratio should be greater than 1 5 1 for this version of the system 2 2 Heat Damage To avoid burning the polarizer film of the liquid crystal panel ensure a panel surface temperature of 80 F is main...

Page 9: ...cinema projector MI HORIZON3D s patented construction three way beam uses three specific Liquid Crystal LC panels that are accurately bonded to ensure effective polarization of the left and right imag...

Page 10: ...3D Inspect the MI HORIZON3D packaging box for any external damage Report any damage to shipper and to MasterImage 3D Head Assembly Outer Carton Box Low Vibration Case for Head Assembly Floor Stand Out...

Page 11: ...l MI HORIZON3D MASTERIMAGE 3D Inc 11 4 2 Confirm Package Contents of MI HORIZON3D Optical Three Way Beam Head Assembly inside Low Vibration Case Floor Stand Actuator Control Box Power Adaptor Sync Cab...

Page 12: ...Installation Operation Manual MI HORIZON3D MASTERIMAGE 3D Inc 12 5 Detailed Component Overview 5 1 Three Way Beam Optical Head Assembly...

Page 13: ...Installation Operation Manual MI HORIZON3D MASTERIMAGE 3D Inc 13 5 2 Actuator Control Box 5 3 Floor Stand...

Page 14: ...3D polarity actuator position Operation LED Displays Running Freq Error Codes 3D Button Used to move the Optical Head Assembly to the 3D position 2D Button Used to move the Optical Head Assembly to th...

Page 15: ...System Assembly 6 1 1 Attach Optical Head to Actuator Insert the optical head assembly into the front section of the actuator tilt stage whilst aligning with the two guide pins Once located correctly...

Page 16: ...Connector from the Actuator assembly to the Optical Head Assembly LC Cable Connection 2 Ensure the Actuator Cable is connected between the Control Box and Actuator and the LC Cable is connected to th...

Page 17: ...Initial Height Adjustment Front Height Locking Screw Side Height Adjustment Screw ALLEN WRENCH TYPE T 6mm Adjust the height of the optical head so the projected light beam coincides with the center o...

Page 18: ...led perpendicular to the light path exiting the lens The angle of this light may not be the same angle as the lens itself so observe the light path from the side to make sure the head is exactly perpe...

Page 19: ...ERIMAGE 3D Inc 19 6 1 4 Locking Feet 6 1 5 GPIO Cable Connect the GPIO cable from the DLP Digital Cinema Projector GPIO Cable Connection Once the height and tilt adjustment has been made lock down all...

Page 20: ...ion Press the 3D button for 2 seconds The actuator moves to the 3D position The 3D button flashes for approx 13 seconds before becoming steady If a GPIO Sync signal is present the LC Panels will becom...

Page 21: ...tical head assembly 2 Load the standard cross hair test pattern from the projector 3 Using a 2mm or 5 64 hex key use the right hand screw to alter the horizontal image position and the left hand screw...

Page 22: ...rojector 3 Using a 2mm or 5 64 hex key use the right hand screw to alter the vertical image position and the left hand screw for the horizontal image position LOWER MIRROR PRISM ADJUSTMENT SCREW VERTI...

Page 23: ...il move the switch to the ON position as indicated to Invert the sync polarity 7 4 Actuator 3D Position If necessary it is possible to change the actuator 3D position by changing the position of DIP s...

Page 24: ...the control files for Series II projectors The Dark Time should be set to 350 S with the Delay being set to 100 S These figures are applicable to all frame rates and projector flash configurations Fo...

Page 25: ...lation Operation Manual MI HORIZON3D MASTERIMAGE 3D Inc 25 8 2 2 Christie Series II File Settings for External Server Playback Christie 8 2 3 Barco Series II File Settings for External Server Playback...

Page 26: ...le Site specific Auxiliary Lens Site specific Selected if Anamorphic Lens or WCL needed otherwise unselected Config 2 Measured Color Site Specific Create on site Target Color DC28_DCI_XYZE_314_351 Col...

Page 27: ...ou can use a different IP address that is suitable to your network 9 2 Execute the Monitor Application using a Web Browser Input the default IP address of the MI HORIZON3D 192 168 10 95 into your web...

Page 28: ...New Password link in the upper right corner of the MI HORIZON3D Web Server and the Change Password dialog box will be displayed MI HORIZON3D Web Server shows all the system status information Status...

Page 29: ...Crystal Panel operation The color of the RUN button will change from black to green The indication under Status will change from Ready to Running Once synchronized the Liquid Crystal Panel operating...

Page 30: ...color of the 3D button will change from black to green The color of the RUN button will change from black to green The indication under Status will change from Ready to Running Whilst the actuator is...

Page 31: ...The color of the 2D button will change from black to green The color of the RUN button will change from green to black The indication under Status will change from Running to Ready Whilst the actuato...

Page 32: ...GE 3D Inc 32 9 5 Sync Polarity via the Monitor Application Check the current value of the Sync Polarity Depending on the condition of 3D material on screen change the Sync Polarity as required from Tr...

Page 33: ...etting 3D Position via the Monitor Application Check the current setting for the 3D position of the Actuator If required by the installation requirements for the system the 3D Position can be changed...

Page 34: ...tem by default this is set to Manual The options available for selection are Manual Control via front panel button GPIO 37 9 Automation via the 37 pin GPIO cable connection GPIO 15 9 Automation via th...

Page 35: ...ource has been set to Sync Pulse click Reference Sync in the bottom left of the application Up to five reference frequencies can be activated and these can be altered from 45 150Hz as required The def...

Page 36: ...with material of varying frequency or frame rate it may be necessary to apply 2D Delay Time to the system to prevent unwanted 2D transition Enter the required 2D Delay Time for your particular situat...

Page 37: ...ation Click Network Configuration to access the settings window Enter the IP Address Gateway Subnet Mask Primary DNS and Secondary DNS of your network accordingly Click the Save Config button to accep...

Page 38: ...RIMAGE 3D Inc 38 9 11 Sync Source via the Monitor Application Check the current setting for the Sync Source The default is GPIO Choose the option for TTL if the system is being used in a non cinema ap...

Page 39: ...tains a log function that stores the last 200 records of activity including any errors that occurred In order to access the log file click Log at the top of the Monitor Application The Log File will b...

Page 40: ...TION GPIO 37 9 Automation Source Setting REFERENCE 1 72Hz Reference Sync Frequency Setting REFERENCE 1 72Hz ON Reference Sync Frequency Enabled REFERENCE 1 72Hz OFF Reference Sync Frequency Disabled P...

Page 41: ...Inc 41 9 13 Factory Default via the Monitor Application Should it be necessary for any reason to reset the system to Factory Default this can be achieved by clicking the Default button This can be co...

Page 42: ...3D Troubleshooting 10 1 Error Indication via LED Display Error code Description E01 No connection with the Actuator E02 No movement of the Actuator normally E03 Malfunction status of the Actuator Chec...

Page 43: ...2 From the MI HORIZON3D folder download and install the MI HORIZON3D firmware upgrading utility Installed shortcut MITftp exe 3 Download and save the latest firmware file having a hex file extension...

Page 44: ...h your individual site network requirements Device s IP Address Default 192 168 10 95 Hex file name Hex file size Log message Upgrade button Exit button Updating progressive bar Open Hex file TFTP Por...

Page 45: ...HORIZON3D MASTERIMAGE 3D Inc 45 4 Click the Open button to select the firmware hex file saved to your PC 5 Select the file to be used and click Open 6 Click the Upgrade button to start the upgrade of...

Page 46: ...g the Upgrade button 8 You will see the Success Firmware Upgrade message in the utility after the progress bar reaches the end Click the Exit button to close the utility after successful upgrade Note...

Page 47: ...NC 3 9 Vertical sync pulse 5 28 PRJ_COM_nUP 4 2 Optical Head Assembly 3D command Low Pulse 200ms 5 21 GND 5 20 21 22 28 29 30 31 Ground PRJ_COM_nDOWN 6 3 Optical Head Assembly 2D command Low Pulse 200...

Page 48: ...15 9 pin Automation DSUB9 GPIO Comm Direction DSUB15 Description Comments Pin name Pin number Pin number NC 1 NC 2 SYNC 3 7 Vertical sync pulse Comparator 24V max 12 threshold LM2901H NC 4 GND 5 13 14...

Page 49: ...ver 1 Within the server menu open Device Manager Menu DTS Digital Cinema Device Manager 2 Click the Add button and the list of devices will display shown right 3 Select the Raw option to create Master...

Page 50: ...o control the MI HORIZON3D The files required are MasterImage Start MasterImage Stop MasterImage 2D MasterImage 3D and MasterImage Up Down Stop These are created in the Macro Editor option of the serv...

Page 51: ...Editor screen Repeat this process for the other four required macros MasterImage Stop MasterImage 2D MasterImage 3D and MasterImage Up Down Stop 3 To insert an action for each newly created macro sel...

Page 52: ...een completed click the OK button 6 Repeat this step for the remaining four macros entering the corresponding message text MasterImage Stop Stop n MasterImage 2D PFD DOWN n or 2D n MasterImage 3D PFD...

Page 53: ...e MasterImage macros will be included in a file named MasterImage_cueslib This will remove the requirement for the information to be entered manually as described in the above steps The MasterImage_cu...

Page 54: ...Installation Operation Manual MI HORIZON3D MASTERIMAGE 3D Inc 54...

Page 55: ...y name Address value address value Key name Port value port value Configuration Device Devices 2 Complete the red fields with the details of the MasterImage MI CLARITY3D where Device Name is MasterIma...

Page 56: ...e 2Dposition Instructions Send PFD Down x0D x0A Send Instructions Method Method name PFDStop Instructions Send PFD Stop x0D x0A Send Instructions Method StreamDevice The symbols x0D x0A are necessary...

Page 57: ...Cue name 3D Position Actions InvokeMethod name 3Dposition device MasterImage Actions Cue Cue name 2D Position Actions InvokeMethod name 2Dposition device MasterImage Actions Cue Cue name Up Down Stop...

Page 58: ...scribed below are specific to the GDC SX 2001 server If information is required for different models please contact GDC directly 1 In the SMS Main Menu click the Control Panel button and log on as Mai...

Page 59: ...peration Manual MI HORIZON3D MASTERIMAGE 3D Inc 59 The MI HORIZON3D must be added as a device within the GDC server configuration 3 Select the Devices tab and click the Add button The following screen...

Page 60: ...enter the configuration settings for the MI HORIZON3D IP Address and Port Number 6 In the Transport option select TCP and in the Linefeed Type select CR and ensure the Status is set to Enabled 7 Once...

Page 61: ...tion Manual MI HORIZON3D MASTERIMAGE 3D Inc 61 9 Click the Add button to create a new event In this case name the event START 10 Click the Enter button and enter the command value for the event Again...

Page 62: ...Event Name UP DOWN STOP Enter Value PFD STOP 12 Once all macros have been created return to the Actions tab of the Automation screen to create the events that are needed to communicate This is done b...

Page 63: ...Installation Operation Manual MI HORIZON3D MASTERIMAGE 3D Inc 63 15 Once all event actions have been created click the Save button followed by Yes...

Page 64: ...below is an example of the installation record form to be filled out once the MI HORIZON3D has been set up and configured For a copy of the form to be filled out contact your equipment provider or em...

Page 65: ...Installation Operation Manual MI HORIZON3D MASTERIMAGE 3D Inc 65 14 Appendix D Dimensional Drawings...

Page 66: ...Installation Operation Manual MI HORIZON3D MASTERIMAGE 3D Inc 66 Optical Head Assembly...

Page 67: ...Installation Operation Manual MI HORIZON3D MASTERIMAGE 3D Inc 67 End of Manual For additional information go to www masterimage3d com...