Page 11
12. MAINTENANCE AND CARE
A minimal amount of care can keep your
battery charger working properly for years.
• Clean the clamps each time you are
finished charging. Wipe off any battery
fluid that may have come in contact
with the clamps to prevent corrosion.
• Occasionally cleaning the case of the
charger with a soft cloth will keep the
finish shiny and help prevent corrosion.
• Coil the input and output cords neatly
when storing the charger. This will help
prevent accidental damage to the cords
and charger.
• Store the charger unplugged from the
AC power outlet in an upright position.
• Store the clamps on the storage areas
provided on the handle. Do not store
the clamps clipped together, on or
around metal, or clipped to the cables.
13. ERROR CODES
CODE
DESCRIPTION
REASON/SOLUTION
bAd
bAT
F01
The battery voltage is still
under 10V (for a 12V battery)
or 5V (for a 6V battery) after 2
hours of charging.
The battery could be bad. Have it checked or
replaced.
SUL
The charger has detected a
sulfated battery.
The charger will go into desulfation mode. If the
desulfation is not successful after 10 hours, the
charger will go into abort mode.
bAd
bAT
F02
The charger cannot desulfate
the battery.
The battery could not be desulfated; have it
checked or replaced.
bAd
bAT
F03
The battery was unable
to reach the “full charge”
voltage.
May be caused by trying to charge a large battery
or bank of batteries on too low of a current setting.
Try again with a higher current setting or have the
battery checked or replaced.
F04
The connections to the
battery are reversed.
The battery is connected backwards. Unplug the
charger and reverse the connections to the battery.
bAd
bAT
F05
The charger was unable to
keep the battery fully charged
in maintain mode.
The battery won’t hold a charge. May be caused by
a drain on the battery or the battery could be bad.
Make sure there are no loads on the battery. If there
are remove them. If there are none, have the battery
checked or replaced.
bAd
bAT
F06
The charger detected that the
battery may be getting too hot
(thermal runaway).
The charger automatically shuts the current off if
it detects the battery may be getting too hot. Have
the battery checked or replaced.
If you get an error code, check the connections and settings and/or replace the battery.