GAS HOOK-UP
19
Only the pressure regulator and hose assembly supplied
with the grill should be used. Any replacement pressure
regulator and hose assembly must be specified by the
grill manufacturer.
7KLVLVDOLTXLGSURSDQHFRQILJXUHGJULOO
'RQRWFRQQHFWWRDQDWXUDOJDVVXSSO\
7
otal gas consumption (per hour) of this grill with all
burners on “IGNI
7
E/MAX”:
Main burner 66,000 Btu/hr.
Side burner 9,000 Btu/hr.
7RWDO%WXKU
7
he installation of this appliance in Canada must be in
accordance with the Standard
(installation code for gas burning appliances and
e
T
uipment) and local codes.
CAN/CSA-B149.2
7
he 20 lb. cylinder must be provided with a shut off valve
terminating in an LP gas supply cylinder valve outlet
specified, as applicable, for connection type
QCC1
is the
standard for compressed gas cylinder valve outlet and
inlet connection ANSI/CSA-V-1.
7
he cylinder supply system must be arranged for vapor
withdrawal.
7
he cylinder must include a collar to protect
the cylinder valve.
A dented or rusty LP Gas Cylinder may be hazardous and
should be checked by your LP supplier. Never use a
cylinder with a damaged valve.
7KH
LP gas cylinder must
be constructed and marked in accordance with the
specifications for LP-Gas Cylinders
of
the
U.S.
'HSDUWPHQW
of
7
ransportation
'27
or the National Standard of
Canada, CAN/CSA-B339, Cylinders, Spheres and
7
ubes
for
7UDQVSRUWDWLRQRI'DQJHURXV*RRGVDQG&RPPLVVLRQ
LP GAS CYLINDER REQUIREMENTS
8VH/3F\OLQGHUVRQO\ZLWKWKHVHUHTXLUHG
PHDVXUHPHQWVFPGLDPHWHU[FP
WDOOZLWKOENJFDSDFLW\PD[LPXP
L
Main Manifold operating pressure: 11” water column (W.C.)/
N3D
P Gas Cylinder must be fitted with Overfill Prevention
'
evice (OP
'
).
The OPD is a flotter device indicating fill level
.
23'F\OLQGHUVDUHLQGHQWLILDEOHE\WKHLUWULDQJXODUYDOYHKDQGO
e.
7KH23'GHYLFHSUHYHQWVRYHUILOOLQJ&\OLQGHUVPXVW127EH
ILOOHGRYHUWKHLUFDSDFLW\
Ensure that the black plastic grommets (seals) on the LP
cylinder valve are in place and that the hose does not
come into contact with the hot grease tray or any hot surface.
1. Make sure cylinder valve is turned OFF turning
clockwise.
2. Check cylinder valve to ensure it has proper e
[
ternal
male threads as picture above ( type 1 ANSI Z21.
1).
3. Make sure all burner valves are in the OFF positions.
4. Inspect valve connections, port and regulator assembly.
Look for any damage or debris. Remove any debris
Inspect hose for damage. Never attempt to use
damaged or obstructed
HTXL
pment. See your local LP
gas dealer for repair.
. When connecting hose regulator assembly to the cylinder
YDOYHGRVRPDQXDOO\GRQRWXVHDWRRO7LJKWHQILUPO\
clockwise by ha
QGRQO\7KHXVHRIDWRROZLOOGDPDJHWKH
seal and cause a serious risk of gas leak.
6. SLOWLY - Open the cylinder valve fully. Proceed to a
leak test (see L
($.7(
S
7
ING section).
LP GAS HOOK-UP
TO CONNECT THE L.P. GAS SUPPLY CYLINDER
QCC1 handwheel - thighten clockwise
by hand only.
([WHUQDOWKUHDGV
(type 1
$16,=
23'WULDQJXODU
handle