15
TM
SETTING THE RE
G
ULA
TOR
How To Set Regulator
1.
2.
3.
4.
Close the Shut Off Valve on the Regulator, and open the CO
2
Tank valve
completely by turning it counter-clockwise.
Slowly turn Pressure Dial all the way to the negative ( - ), then pull the Pressure
Relief Valve (PRV) to ensure an accurate reading. Then very slowly turn the
Pressure Dial clockwise until the desired pressure is shown on the Output
Pressure Gauge (8-12 PSI is recommended).
»
Turning clockwise will increase the output pressure (higher PSI).
»
Turning counter-clockwise will decrease the output pressure (lower PSI).
Once desired pressure is reached, tighten the inner Locking Ring. Pull the PRV to
assure the correct setting. If necessary, readjust your settings.
Next, open the CO
2
Shut Off Valve on the Regulator to allow gas to flow from
the Regulator to the Keg Coupler. You will hear the keg pressurizing. The output
needle will drop momentarily until the pressure has equalized. Then the needle will
return to the point you set it at.
Finally, we suggest you re-check the output pressure on the Regulator, and if necessary re-adjust starting at
step #1 until the desired pressure is reached.