8
CONDENSATE PAN INSTALLATION FOR TOP MOUNT CABINETS ONLY
1. Before moving cabinet into place,
remove the condensate pan from
the top unit compartment.
2.
Using the two screws supplied with
the pan, attach the pan to the back
of the cabinet at the two holes near
the bottom of the plastic drain line.
Be sure pan is NOT located directly
under cabinet. When the pan is
attached, feed drain line into the
open hole in screen and clamp the
heater conduit to the back of the
cabinet. Due to this condensate
pan, this case must be a minimum
of 6” from the wall.
3. If cabinet must be located next to
wall on legs, the pan can be located
under the cabinet. When this is
done, steam will accumulate on the
bottom of the cabinet if there is not
adequate ventilation, and rusting of
the bottom of the cabinet will occur.
Low Temperature Freezers – TAF Models
The
TAF - 27
models are cord connected and operate on a 15 amp, 115/60/1 circuit. The
TAF – 48
models are
cord connected and operate on a 20 amp, 115/60/1 circuit. The
TAF – 74
models have two junction boxes
mounted on top of the cabinet at the right rear for permanent connection to power. One junction box is labeled
115v. (black,white and green lead) ; the other is labeled 230v. (black,red and green lead). These boxes should
be connected to their respective power source.
Check inside the cabinet for the power requirement for each cabinet. The label is located in the upper left hand
corner. These
TAF
models are equipped with timers and electric defrost with a defrost termination and fan
delay thermostat. Because of this thermostat, on initial start up the evaporator fan motors will not start and you
cannot initiate a defrost until the cabinet temperature is lowered to 10
°
F to 20
°
F
The temperature thermostat on the
TAF
models does not have an “Off” position, so the condensing unit will
start up immediately when the power is connected to the cabinet.
Medium Temperature Refrigerators (TAC Models)
All
TAC
models are equipped with a 115/60/1 lead cord and plug cap. When connected to power, the
condensing unit and evaporator fan (s) will start. The mullion heaters will heat and, when the door is opened,
the lights will be energized.
Summary of Contents for TAF-27