Once a memory or preset is loaded, it will remain in the memory even is the
equipment is powered off. Next time the unit is powered on, the last loaded memory
will be used. After some seconds of inactivity of the keypad, the keypad and LCD will
automatically lock.
b) With external PC
. Once the required connections between the cabinets and PC
are made, the cabinets can be controlled by the PC. All functions described above
plus 5 parametric EQ or filters (Butt-LR-Shelf) can be configured.
For more information about the software and the connections required, please refer to
the DSPController Manual or Quick Installation Guide, available at your dealer or at
Master Audio’s technical service:
8. MOUNTING AND INSTALLATION
Whenever possible, mount the Full Range units in a high position (between 2 and 3
meters above ground), angled towards the audience. If the units are mounted close to
the ground the back row listeners will receive low quality sound.
Due to the coaxial technology design the cabinets must be oriented so that the
central angle axis (0º) is directly focused at the rear part of the audience. Thus all the
high frequency energy is directed towards the furthest spectators; those the front
rows will receive high frequencies generated beyond the acoustic axis, with a more
acute yet balanced, equalized level in respect to the back rows.
Fig.9. Orientation of Xcellence full range units(X-12C, X-15C)
The X-12C and X-15C models incorporate a 35mm pole mount socket for standard
tripod in the upper and lower sides.
To use the socket, unscrew the four bolts on the central face plate.
Fig.15. Socket for tripod