5.3 Diode Measurement

To avoid the meter or measured equipment from 
being damaged, cut off all power supply of 
measured circuits and discharge all high voltage
capacitors before measuring diode.

Warning

The method of measuring diode is:

1.Turn rotary switch to        position.
2.Press        key and select       measuring range.
3.Separately connect black and red test leads to 
   negative pole and positive pole of measured diode.
4.The meter shall display forward bias value of 
    measured diode.If the poles of the test leads are 
    connected inversely, the meter will display “OL”.

Notice

:

For on-line measuring diode, display forward voltage 
drop at forward measurement; the reverse measurement 
depends on the values of other elements connected in 
parallel at both ends of diode.

5.4 Continuity Measurement

To avoid the meter or measured equipment from 
being damaged,cut off all power supply of 
measured circuits and discharge all high voltage 
capacitors before continuity measurement.

Warning

The method of continuity measurement is:

1.Turn

 

rotary

 

switch

 

to

        

position,.

2.Press

        

key

 

and

 

select       measuring range.

3.Separately connect two ends of test leads to the two 
   ends of measured part and circuit.
4.The

 

meter

 

shall

 

display

 

the

 

approximate

 

resistance

 

    

value

 

between measured

 

points.Here

 

if

 

the

 

resistance

 

    

value

 

between

 

measured

 

points is

 

less

 

than

 

50±20

Ω

,

    

the

 

buzzer

 

will

 

make

 

a

 

sound.

5.5 Capacitance Measurement

To avoid the meter or measured equipment from 
being damaged,cut off all power supply of 
measured circuits and discharge all high voltage 
capacitors before on/off measurement.

Warning

The capacitance ranges of the meter are:
40.00nF, 400.0nF, 4.000uF, 40.00uF, 100.0uF.

The method of measuring capacitance is:

1.Turn rotary switch to        position, 
2.Press        key and select       measuring range.
3.Apply the two ends of test leads to measure the two 
   pins of the capacitance under test and read measured 
   value from LCD.

Notice:

1.The meter shall take some time to stabilize the reading 
   when high capacitance.
2.The small capacitance with less than 10nF shall minus 
   the distribution capacitance of the meter and lead 
   (namely displayed base number) when measuring.
   measuring

Summary of Contents for MS8332C

Page 1: ...MS8332C Digital Multimeter User Manual CAT III 600 V...

Page 2: ...5 4 2 Electrical Technical Index 5 5 Measuring Operations 9 5 2 Resistance Measurement 10 5 1 AC Voltage and DC Voltage Measurement 9 5 3 Diode Measurement 11 5 4 Continuity Measurement 11 5 5 Capacit...

Page 3: ...The special attention should be paid when using the meter because the improper usage may cause electric shock and damage the meter The safety measures in common safety regulations and operating instr...

Page 4: ...o hold the data Press this key 2 second to open the backlight 3 3 Symbols 3 Product Overview 3 1 Product External View 1 Non contact AC Voltage Indicator Light 2 LCD Display 3 HOLD backlight Key 4 Fun...

Page 5: ...32 104 relative humidity 80 RH Storage temperature and humidity 10 50 14 122 relative humidity 70 RH Altitude 2000m Power Supply AAA 2 1 5V Battery Safety Class EN61010 1 CAT III 600V Dimension LxWxH...

Page 6: ...y 4000uA 40mA 400mA 10uA 1uA 100uA 400uA 0 1uA Max Current 400mA Overload Protection mA measuring range FF 400mA H 600V 10KA fuse Frequency Range 40 400Hz Response Average value r m s of sine wave 2 0...

Page 7: ...f outside interference but its normal usage and measuring accuracy will not be affected 5 2 Resistance Measurement In order to avoid the meter or measured equipment from being damaged cut off all powe...

Page 8: ...ing The method of continuity measurement is 1 Turn rotary switch to position 2 Press key and select measuring range 3 Separately connect two ends of test leads to the two ends of measured part and cir...

Page 9: ...suring resistance is 1 Cut off the power of measured circuit Discharge all high voltage capacitance on measured circuit 2 Turn rotary switch to mA or uA position When the measured current is less than...

Page 10: ...H 600V 10KA Don t use the instrument until the rear cover is placed back and the screws are tightened Clean the housing of instrument only with a wet rag dripped with little detergent but never chemic...

Reviews: