MS8218 True RMS Multimeter
Technological Specifications
Range and Accuracy
The below-listed accuracies under different ranges refer to those which are guaranteed by the meter within one-year calibration,
with normal use under the operating temperature of 18
℃
-28
℃
and relative humidity less than 80%.The presentation for
accuracy is:
±
(**% reading number of lower digits)
●
AC Voltage/DC V AC Voltage
Accuracy
Range
Resolution
40Hz-1KHz
1KHz-10KHz
10KHz-20KHz
50mV
0.001mV
±
(0.5% + 40)
±
(1% + 40)
±
(2.5% + 40)
500mV
0.01mV
±
(0.5% + 40)
±
(1% + 40)
±
(2.5% + 40)
5V
0.1mV
±
(0.5% + 40)
±
(1% + 40)
±
(2.5% + 40)
50V
1mV
±
(0.5% + 40)
±
(1% + 40)
±
(2.5% + 40)
500V
10mV
±
(0.5% + 40)
±
(1% + 40)
unspecified
1000V
0.1V
±
(0.5% + 40)
unspecified
unspecified
Notes: above accuracies can be guaranteed within 10%-100% of the full range.
●
DC Voltage
Range
Resolution
Accuracy
50mV
0.001mV
±
(0.03%+10)
500mV
0.01mV
±
(0.03%+6)
5V
0.1mV
±
(0.03%+6)
50V
1mV
±
(0.03%+6)
500V
10mV
±
(0.03%+6)
1000V
0 .1V
±
(0.03%+6)
Notes: above accuracies can be guaranteed within`the full range