![Mastech MS8218 Instruction Manual Download Page 40](http://html1.mh-extra.com/html/mastech/ms8218/ms8218_instruction-manual_1736124040.webp)
MS8218 True RMS Multimeter
Technological Specifications
Chapter 4 Technological Specifications
General Features
●
Voltage between the measurement end and ground is of 1000V AC/DC. 1000V CAT
Ⅲ
, 2th pollution grade.
●
50000 counts, automatic/manual range, basic sampling rate 2.5 t/s and 51 segment analog bar.
●
When rotary switch being in the positions of mV, logic frequency, diode, resistance and capacitance, the maximum
overload protection voltage will be 250V(effective value),while in the positions of
μ
A/mA the protection current being
0.64A,and in the position of A, the protection current being 12.5A.
●
Over range indication OL.
●
When the total voltage of batteries being lower than 6.8V, the symbol for battery display will be lighted.
●
Fuse being 0.63A/500V(
μ
A/mA end) and 12.5A/500V (A end).
●
Six 7# AA batteries X 1.5V.
●
Infrared coupling RS-232C interface.
●
Operating temperature: 0
℃~
~
~
~
30
℃
(relative humidity 0
~
~
~
~
80%)
31
℃~
~
~
~
51
℃
(relative humidity 0
~
~
~
~
50%)
●
Storage temperature: -20
℃~
~
~
~
60
℃
(relative humidity <= 80%)
●
Altitude: operation less than 2000m,
storage less than 10000m
●
Volume
:
200mm X 100mm X 40mm
●
Weight
:
560g
38