12
network. Turn the switch to “TONE” mode and the “TONE” indicator turns red. Move
the receiver antenna close the target network cable, press and hold the power button
on the receiver. Adjust receiver volume through sensitivity switch. Network is well
connected if the receiver makes buzz sound.
1.3
Network Cable Tracking
WARNING
TO AVOID ELECTRICAL SHOCK AND INJURY, DO NOT CONNECT RECEIVER TO ANY
AC SIGNAL LARGER THEN 24V.
2.3.1 Sending Audio Frequency Signal:
Connect both leads
(“RJ45” Adaptor
、
“BNC” Adaptor
、
“RJ11” Adaptor
、
the red lead and
back lead)
on the transmitter to the network cable (or connect the red lead to target
cable and black lead to ground depends on the circuit). Turn the transmitter switch to
“TONE” mode and the indicator will lights up. Press and hold receiver power button,
move the receiver close to the target network to receive signal. Adjust receiver volume
through sensitivity switch.
2.3.2 Tracking Network Cable
Use “TONE” mode on transmitter along with the receiver to track cable. Connect the wire
adaptor to the target network (or connect the red lead to target cable and black lead to
ground depends on the circuit). Switch to “TONE” mode on the transmitter, “TONE” indicator
turns on. Press and hold the power button on the receiver. Move the receiver near the target
network to receive audio frequency signal. The Tester detects the direction and continuity of
the network cable. Adjust receiver volume through sensitivity switch.