Resistance

TO AVOID ELECTRICAL SHOCK AND INJURY, TURN 
OFF POWER TO THE CIRCUIT AND DISCHARGE ALL
CAPACITORS BEFORE MEASURING RESISTANCE.

WARNING:

1.Insert the black test lead into “

COM”

 jack and red test 

    lead into “

INPUT” 

jack.

2.Turn the rotary switch to the      

 

position.

3.Connect the test leads across the circuit to be tested.
4.Read the measured resistance value on the display.

Note:
• 

If the resistance is too high or the test leads are 

  disconnected, the display shows “

OL

”.

• 

The meter may take several seconds to get a steady 

  reading if the resistance being measured is more than 
  1M

Ω

.This is normal for high resistance circuits. 

Continuity 

TO AVOID ELECTRICAL SHOCK AND INJURY, TURN 
OFF POWER TO THE CIRCUIT AND DISCHARGE ALL 
CAPACITORS BEFORE MEASURING CONTINUITY.

WARNING:

1.Insert the black test lead into “COM” jack and red test 
    lead into “INPUT” jack.
2.Turn the rotary switch to the      

 

position.Press “FUNC” 

    to switch to continuity mode.
3.Connect the test leads across the circuit to be tested.
4.Read the measured resistance value on the display. 
5.If the resistance is less than 50

Ω

, the meter’s buzzer 

    will sound. 

Note:

If the resistance is higher than 60M

Ω 

or the leads are 

disconnected, the display shows “

OL

”. 

Capacitance

TO AVOID ELECTRICAL SHOCK AND INJURY, TURN 
OFF POWER TO THE CIRCUIT AND DISCHARGE ALL
CAPACITORS BEFORE MEASURING CAPACITANCE.

WARNING:

1.Insert the black test lead into “

COM”

 jack and red test 

    lead into “

INPUT” 

jack.

2.Turn the rotary switch to the      

 

position.Press "

FUNC

    twice to switch to capacitance mode.
3.Connect the test leads across the circuit to be tested.
4.Read the measured resistance value on the display. 

Note:
• 

For better accuracy on measurements below 10nF, touch

  the tips of the leads together before measurement and 
  subtract the distributed capacitance of the meter from the 
  actual measurement.

• 

For measurements on large capacitances, allow up to 30 

  seconds for the reading to stabilize.

Diodes

1.Insert the black test lead into “

COM”

 jack and red test 

    lead into “

INPUT” 

jack.

2.Turn the rotary switch to the      

 

position.Press "

FUNC

    three times to switch to diode mode.
3.Connect the red lead to the anode (+) and the black 
    lead to the cathode (-).
4.Read the measured forward biased voltage drop on the 
   display. 

Note:
• 

If the leads are connected backwards or to an open 

  circuit, the display will show 

“OL”

.

Summary of Contents for MS2601

Page 1: ...MS2601 Electrical Tester User s Manual CAT III 600 V 600V CAT III Hz A V Loz A Temp FUNC RAN Hz NCV MS2601 ELECTRICALTESTER 600V CAT III COM MAX 200A Temp A...

Page 2: ...ode 7 Backlight and worklight 8 Auto Power Off 8 Measurement Preparation 8 AC Current 9 Switching Between Functions 7 AC DC Voltage 10 Resistance 11 Diodes 12 Continuity 11 Capacitance 12 Non Contact...

Page 3: ...ument to Mastech no service will be provided without a return authorization The user is responsible for properly packing the unit and charges such as shipping freight and insurance charges The extent...

Page 4: ...e circuit first before switching between functions 12 Disconnect power and discharge all capacitors before measuring resistance capacitance continuity or diodes 13 Do not measure capacitance before th...

Page 5: ...een functions RAN button to switch to manual range button to hold the reading or to turn on backlight Hz button to switch between frequency and duty cycle NCV button to activate non contact voltage de...

Page 6: ...t automatically turns off To turn off the backlight manually hold again When the meter is in current mode turning on the backlight will also activate the worklight making it easier to use the clamp in...

Page 7: ...into INPUT jack 2 Turn the rotary switch to the V The default mode is DC voltage press FUNC to switch to AC voltage if necessary press FUNC to switch back to DC voltage 3 Connect the test leads across...

Page 8: ...istance is less than 50 the meter s buzzer will sound Note If the resistance is higher than 60M or the leads are disconnected the display shows OL Capacitance TO AVOID ELECTRICAL SHOCK AND INJURY TURN...

Page 9: ...lead into INPUT jack 2 Turn the rotary switch to the position Press FUNC to switch to AC voltage 3 Press Hz button to measure frequency 4 Press Hz again to measure duty if necessary 5 Connect the test...

Page 10: ...ault mode is F press FUNC to switch to C if necessary press FUNC to switch back to F 3 Touch the tip of the thermocouple to the object to be tested 4 Read the measured temperature value on the display...

Page 11: ...true reading will be shown 600mV 0 1mV 1000 A AC Voltage 0 8 reading 3 digits Range Resolution Accuracy 6V 0 001V 60V 0 01V 600V 0 1V Input impedance 10M Maximum input voltage 600V DC AC rms Frequency...

Page 12: ...measured resistance is less than 50 0 1 Description Function Resolution Continuity Over voltage protection 250V DC AC rms Diodes Displays forward biased voltage drop 0 001V Description Function Resolu...

Page 13: ...meter or personal injury To avoid electrical shock remove test leads from input jacks before cleaning To avoid false readings that could lead to possible electric shock replace the batteries as soon...

Page 14: ...electric shock make sure the probes are disconnected from the measured circuit before removingthe rear cover Make sure the rear cover is tightly screwed before using the instrument Warning Out of the...

Reviews: