background image

MS2600

DIGITAL CLAMP METER

OPERATION MANUAL

REL

Hz

/

HOLD

F.

FUNC.

R.

RANGE

MAX 200A

600V CAT III  

600V CAT. III

A

V

OFF

V

Hz

Press 2 Sec

COM

V Hz

TESTER

ELECTRICAL

AUTO - POWER OFF

AUTO RANGING

CAT III

600 V

Summary of Contents for MS2600

Page 1: ...MS2600 DIGITAL CLAMP METER OPERATION MANUAL REL Hz HOLD F FUNC R RANGE MAX 200A 600V CAT III 600V CAT III A V OFF V Hz Press 2 Sec COM V Hz TESTER ELECTRICAL AUTO POWER OFF AUTO RANGING CAT III 600 V ...

Page 2: ...STING 7 OPERATING INSTRUCTIONS 8 8 7 1 DC VOLTAGE MEASUREMENT 7 2 AC VOLTAGE MEASUREMENT 8 3 5 GENERAL DESCRIPTION 3 6 PANEL DESCRIPTION 10 7 7 CAPACITANCE MEASUREMENT 10 7 8 MEASURING FREQUENCY 11 7 9 DUTY CYCLE TEST 8 3 AC VOLTAGE 12 8 SPECIFICATIONS 11 11 8 1 GENERAL 8 2 DC VOLTAGE 12 8 6 CAPACITANCE MEASUREMENT 13 12 8 4 AC CURRENT 8 5 RESISTANCE 13 14 8 7 FREQUENCY MEASUREMENT 8 8AUDIBLE CONT...

Page 3: ......

Page 4: ...function with auto and manual mode is selected the meter enters auto range at first To change to manual range push this button once 6 1Transformer jaws Pick up the AC current flowing through the conductor 6 2Hold button When this button is pushed the display will keep the last reading and symbol will appear on the LCD until pushing it again When this button is pressed more than two second the ligh...

Page 5: ...surement unit Duty cycle measurement indication Hz 6 6 VHz jack This is positive input terminal for volt diode resistance frequency duty cycle and capacitance measurement connection is made to it using the red test lead 6 7 COM jack This is negative ground input terminal for all measurement modes except current Connection is made to it using the black test lead 6 8 LAYOUT FORWARD REL Hz HOLD F FUN...

Page 6: ... PENDING OPERATE WITH OPEN BATTERY COVER EMC LVD DC 9V NEDA 1604 6F22 006P WARNING MEETS IEC1010 1 IEC1010 2 032 TO AVOID ELECTRICAL SHOCK DO NOT PATENT PENDING OPERATE WITH OPEN BATTERY COVER EMC LVD DC 9V NEDA 1604 6F22 006P WARNING MEETS IEC1010 1 IEC1010 2 032 1000V CAT III 10A ...

Page 7: ...on OL will be displayed NOTE When checking in circuit resistance be sure the circuit under test has all power removed and that all capacitors have been discharged fully For measuring resistance above 1M the meter may take a few seconds to get stable reading This is normal for high resistance measurements When the input is not connected i e at open circuit the figure OL will be displayed for the ov...

Page 8: ......

Page 9: ...Ω ...

Page 10: ...onnect test leads from any live source and remove the test leads from the input terminals 2 R emove screws on the battery cover and open the cover 3 R emove the exhausted battery and replace with a new 9 voltage battery IEC 6F22 JIS 006P NEDA 1604 type 4 N ever use the multimeter unless the battery cover is in place and fastened fully 11 ACCESSORIES Operator s instruction manual Set of test leads ...

Reviews: