Mastech MS20006 User Manual Download Page 7

12

13

Polarity indication 

“-”displayed for negative 
polarity

Overrange Indication 

Only figure “1” on the display

Jaw opening capability 

55mm (Max conductor size)

Power 

9V battery, NEDA 1604 or 
IEC 6F22 

Low battery indication 

“      ” appears on the display

Operating Environment  

0 to 40°C

Storage temperature 

-10°C to 50°C

Temperature coefficient 

0.1×specified accuracy) /
 °C ( <18°C or >28°C )

Altitude 

 2000m

Size 

282mm×104mm×47mm 

Weight 

Approx.570g.

DC VOLTAGE

Range 

2V

20V

200V

1000V

Resolution 

1mV

10mV

0.1V

1V

Accuracy 

±0.5% of rdg ± 1 digit 

±1.0% of rdg ± 2 digit 

Input Impedance: 10M

Ω

AC VOLTAGE

Range 

200V

750V

Resolution 

0.1V

1V

Accuracy 

±1.0% of rdg ± 3 digit 

Input Impedance: 10M

Ω

Frequency range: 40Hz to 400Hz. 
Response: Average responding, calibrated in rms. of sine 

wave.

AC CURRENT

Range 

200A

2000A

Resolution 

0.1A

1A

Accuracy 

±2.0% of rdg ± 5 digit 

Overload Protection: 2200A for 60 seconds maximum.
Frequency range: 50Hz to 60Hz.

<600A  ±2.0% of rdg ± 5 digits
600A to1000A  ±3.0% of rdg ± 5 digits
>1000A  ±3.0% of rdg ± 15 digits
 

RESISTANCE

Range 

200

Ω

20k

Ω

Resolution 

0.1

Ω

10

Ω

Accuracy 

±1.0% of rdg ± 3 digit 

2M

Ω

1k

Ω

±1.5% of rdg ± 15 digit 

±1.5% of rdg ± 15 digit 

Summary of Contents for MS20006

Page 1: ...ETER MASTECH HOLD SAFETY INFORMATION 2 SAFETY SYMBOLS 2 SAFETY PRECAUTIONS 3 MAINTENANCE 4 GENERAL DESCRIPTION 4 FRONT PANEL DESCRIPTION 5 OPERATING INSTRUCTIONS 8 SPECIFICATIONS 11 REPLACING THE BATTERY 12 ACCESSORIES 13 CONTENTS ...

Page 2: ...ate precautions to avoid misleading Follow all safety and operating instructions to ensure maximum personal safety during the operation and to ensure the meter is used safely and is kept in good operating condition Read these operating instructions thoroughly and completely before operating your meter Pay particular attention to WARNINGS which will inform you of potentially dangerous procedures Th...

Page 3: ...trained and another person capable of rendering first aid and resuscitation is present MAINTENANCE The meter is a handheld 31 2 digital clamp meter for GENERAL DESCRIPTION measuring DC and AC voltage AC current Resistance Frequency Temperature C F Diode and Continuity Test with battery operated Transformer jaws Pick up the AC current flowing through the conductor Hold button When this button is pu...

Page 4: ...inal for ohms Connection is made to it using the red test lead Temperature Measuring Socket Insert a K type thermocouple into the temperature measuring socket and contact the object to be measured with the thermocouple probe Trigger Press the lever to open the transformer When the lever is released the jaws will close again 7 8 9 10 MASTECH HOLD 06 CLAMP METER LAYOUT 1 2 3 4 5 6 8 9 10 7 ...

Page 5: ...ent value on LCD display RESISTANCE MEASUREMENT 1 Connect the red test lead to Ω jack and black test lead to the COM jack The polarity of red lead is positive 2 Set the rotary switch at desired Ω range position 3 Connect test leads across the resistor to be measured and read LCD display 4 If the resistance being measured is connected to a circuit turn off power and discharge all capacitors before ...

Page 6: ...input 2 In noisy environment it is preferable to use shield cable for measuring small signal DIODE TEST 1 Connect the red test lead to Ω jack and the black test lead to the COM jack The polarity of red lead is positive 2 Set the rotary switch at position 3 Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode 4 The approx forward volta...

Page 7: ...00V 1000V Resolution 1mV 10mV 0 1V 1V Accuracy 0 5 of rdg 1 digit 1 0 of rdg 2 digit Input Impedance 10MΩ AC VOLTAGE Range 200V 750V Resolution 0 1V 1V Accuracy 1 0 of rdg 3 digit Input Impedance 10MΩ Frequency range 40Hz to 400Hz Response Average responding calibrated in rms of sine wave AC CURRENT Range 200A 2000A Resolution 0 1A 1A Accuracy 2 0 of rdg 5 digit Overload Protection 2200A for 60 se...

Page 8: ...y should be replaced Use the following procedure to replacing the battery 1 Disconnect test leads from any live source turn the rotary switch to OFF and remove the test leads from the input terminals 2 The battery cover is secured to the bottom case by a screw Using a screwdriver remove the screw from the battery cover and remove the battery cover 3 Remove battery and replace with a new equivalent...

Reviews: