Mastech MS20006 User Manual Download Page 5

1.Connect the red test lead to the “VHz” jack and the
    black lead to the “COM” jack.
2.Set rotary switch at desired V      position. 
3.Connect test leads across the source or load being
    measured.
4.Read voltage value on the LCD display along with the
    polarity of the red lead connection.

OPERATING INSTRUCTIONS 
DC VOLTAGE MEASUREMENT 

AC VOLTAGE MEASUREMENT

1.Connect the red test lead to “VHz” jack and the black

 test lead to the “COM” jack.

2.Set the rotary switch at desired V~ position.
3.Connect test leads across the source or load being

  

 measured.

4.Read voltage value on the LCD display.

AC CURRENT MEASUREMENT

1.Set the rotary switch at desired A~ position.
2.Press the trigger to open transformer jaw and to

 

 clamp one conductor only, making sure that the jaw 

  

is firmly closed around the conductor.

3.Read current value on LCD display.

RESISTANCE MEASUREMENT

1.Connect the red test lead to “

Ω

” jack and black test

    lead to the “COM” jack. (The polarity of red lead is
    positive “+”.) 
2.Set the rotary switch at desired ”

Ω

” range position.

3.Connect test leads across the resistor to be
    measured and read LCD display.
4.If the resistance being measured is connected to a

  

 circuit

,

turn off power and discharge all capacitors

  

 before applying test probes.

NOTE:

1.If the resistance being measured exceeds the

 maximum value of the range selected or the input is

 

not connected, an overrange indication “1”will be

 displayed.

2.When checking in-circuit resistance, be sure the

  

 circuit under test has all power removed and that all

  

 capacitors have been discharged fully.

3.For measuring resistance above 1M

Ω

, the meter may

  

take a few seconds to get stable reading. This is

  

normal for high resistance measurements.

MEASURING TEMPERATURE

1.Set the rotary switch at °C or °F Position. The LCD
   display will show the current environment 
   temperature.

Summary of Contents for MS20006

Page 1: ...ETER MASTECH HOLD SAFETY INFORMATION 2 SAFETY SYMBOLS 2 SAFETY PRECAUTIONS 3 MAINTENANCE 4 GENERAL DESCRIPTION 4 FRONT PANEL DESCRIPTION 5 OPERATING INSTRUCTIONS 8 SPECIFICATIONS 11 REPLACING THE BATTERY 12 ACCESSORIES 13 CONTENTS ...

Page 2: ...ate precautions to avoid misleading Follow all safety and operating instructions to ensure maximum personal safety during the operation and to ensure the meter is used safely and is kept in good operating condition Read these operating instructions thoroughly and completely before operating your meter Pay particular attention to WARNINGS which will inform you of potentially dangerous procedures Th...

Page 3: ...trained and another person capable of rendering first aid and resuscitation is present MAINTENANCE The meter is a handheld 31 2 digital clamp meter for GENERAL DESCRIPTION measuring DC and AC voltage AC current Resistance Frequency Temperature C F Diode and Continuity Test with battery operated Transformer jaws Pick up the AC current flowing through the conductor Hold button When this button is pu...

Page 4: ...inal for ohms Connection is made to it using the red test lead Temperature Measuring Socket Insert a K type thermocouple into the temperature measuring socket and contact the object to be measured with the thermocouple probe Trigger Press the lever to open the transformer When the lever is released the jaws will close again 7 8 9 10 MASTECH HOLD 06 CLAMP METER LAYOUT 1 2 3 4 5 6 8 9 10 7 ...

Page 5: ...ent value on LCD display RESISTANCE MEASUREMENT 1 Connect the red test lead to Ω jack and black test lead to the COM jack The polarity of red lead is positive 2 Set the rotary switch at desired Ω range position 3 Connect test leads across the resistor to be measured and read LCD display 4 If the resistance being measured is connected to a circuit turn off power and discharge all capacitors before ...

Page 6: ...input 2 In noisy environment it is preferable to use shield cable for measuring small signal DIODE TEST 1 Connect the red test lead to Ω jack and the black test lead to the COM jack The polarity of red lead is positive 2 Set the rotary switch at position 3 Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode 4 The approx forward volta...

Page 7: ...00V 1000V Resolution 1mV 10mV 0 1V 1V Accuracy 0 5 of rdg 1 digit 1 0 of rdg 2 digit Input Impedance 10MΩ AC VOLTAGE Range 200V 750V Resolution 0 1V 1V Accuracy 1 0 of rdg 3 digit Input Impedance 10MΩ Frequency range 40Hz to 400Hz Response Average responding calibrated in rms of sine wave AC CURRENT Range 200A 2000A Resolution 0 1A 1A Accuracy 2 0 of rdg 5 digit Overload Protection 2200A for 60 se...

Page 8: ...y should be replaced Use the following procedure to replacing the battery 1 Disconnect test leads from any live source turn the rotary switch to OFF and remove the test leads from the input terminals 2 The battery cover is secured to the bottom case by a screw Using a screwdriver remove the screw from the battery cover and remove the battery cover 3 Remove battery and replace with a new equivalent...

Reviews: