DC VOLTAGE   

Range Resolution 

Accuracy 

200mV 100

μ

±

0.5% of rdg 

±

 2 digits 

2V 1mV 

±

0.5% of rdg 

±

 2 digits 

20V 10mV 

±

0.5% of rdg 

±

 2 digits 

200V 100mV 

±

0.5% of rdg 

±

 2 digits 

600V 1V 

±

0.8% of rdg 

±

 2 digits 

Overload Protection: 250V rms. For 200mV range and 600V dc 
or rms. ac for other ranges. 

 

DC CURRENT 

Range Resolution 

Accuracy 

200

μ

A 0.1

μ

±

1% of rdg 

±

 2 digits 

2mA 1

μ

±

1% of rdg 

±

 2 digits 

20mA 10

μ

±

1% of rdg 

±

 2 digits 

200mA 100

μ

±

1.5% of rdg 

±

 2 digits 

10A 10mA 

±

3% of rdg 

±

 2 digits 

Overload Protection: F 200mA/250V fuse. (10A range unfused) 

 

AC VOLTAGE 

Range Resolution 

Accuracy 

200V 100mV 

±

1.2 % of rdg 

±

 10 digits 

600V 1V 

±

1.2 % of rdg 

±

 10 digits 

Overload Protection: 600V dc or rms. ac for all ranges. 
Frequency range: 40Hz to 400Hz. 

 

RESISTANCE 

Range Resolution 

Accuracy 

200

Ω

 0.1

Ω

 

±

0.8% of rdg 

±

 3 digits 

2k

Ω

 

1

Ω

 

±

0.8% of rdg 

±

 2 digits 

20k

Ω

 10

Ω

 

±

0.8% of rdg 

±

 2 digits 

200k

Ω

 100

Ω

 

±

0.8% of rdg 

±

 2 digits 

2M

Ω

 1k

Ω

 

±

1.0% of rdg 

±

 2 digits 

Maximum Open Circuit Voltage: 3.2V 
Overload Protection

:

 250V dc or rms. ac for all ranges. 

-5- 

Summary of Contents for MAS830B

Page 1: ...OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER ...

Page 2: ...ied in this manual SAFETY SYMBOLS Important safety information refer to the operating manual Dangerous voltage may be present Earth ground Double insulation Protection class II Fuse must be replaced with rating specified in the manual MAINTENANCE Before opening the case always disconnect test leads from all energized circuits For continue protection against fire replace fuse only with the specifie...

Page 3: ...ements on TV or switching power circuits always remember that there may be high amplitude voltages pulses at test points which can damage the meter Always is careful when working with voltages above 60V dc or 30V ac rms Keep fingers behind the probe barriers while measuring Before attempting to insert transistors for testing always be sure that test leads have been disconnected from any measuremen...

Page 4: ...FRONT PANEL 3 ...

Page 5: ...ctor for red positive test lead for voltage resistance and current except 10A measurements SPECIFICATIONS Accuracy is specified for a period of one year after calibration and at 18 to 28 64 F to 82 F with relative humidity to 80 GENERAL Maximum voltage CATⅡ 600V Fuse protection F 200mA 250V Power 9V battery NEDA 1604 or 6F22 Display LCD 1999 counts updates 2 3 sec Measuring method Dual slope integ...

Page 6: ...dg 2 digits 200mA 100μA 1 5 of rdg 2 digits 10A 10mA 3 of rdg 2 digits Overload Protection F 200mA 250V fuse 10A range unfused AC VOLTAGE Range Resolution Accuracy 200V 100mV 1 2 of rdg 10 digits 600V 1V 1 2 of rdg 10 digits Overload Protection 600V dc or rms ac for all ranges Frequency range 40Hz to 400Hz RESISTANCE Range Resolution Accuracy 200Ω 0 1Ω 0 8 of rdg 3 digits 2kΩ 1Ω 0 8 of rdg 2 digit...

Page 7: ...urce or load being measured Read voltage value on the LCD display along with the polarity of the red lead connection DC CURRENT MEASUREMENT 1 2 3 4 Connect the red test lead to the V Ω mA jack and the black test lead to COM jack For measurements between 200mA and 10A move red lead to 10A jack Set the rotary switch at desired DCA position Open the circuit in which the current is to be measured and ...

Page 8: ... lead is positive Set the rotary switch at position Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode The approx forward voltage drop of the diode will be displayed If the connection is reversed only figure 1 will be shown TRANSISTOR TEST 1 2 3 Set the rotary switch at hFE position Determine whether the transistor under testing is ...

Page 9: ...om of the case Simply remove the old and replace with a new one Be careful to observe battery polarity WARNING Before attempting to open the case always be sure that test leads have been disconnected from measurement circuits Close case and tighten screws completely before using the meter to avoid electrical shock hazard ACCESSORIES Operator s instruction manual Set of test leads Gift box 9 volt b...

Page 10: ...HYS004609 A1 ...

Reviews: