Operating instructions for Cable Detector, article 37270766
Page
31
of
34
7.
Technical parameters
7.1 Technical parameters of the transmitter
Output signal
125kHZ
External voltage identification range
DC 12~400V±2.5%; AC 12~400V(50-60Hz±2.5%;
Display
LCD with function display and column diagram
Dielectric stability, external voltage
Max. 400V AC/DC
Overvoltage type
CAT III 300V
Degree of contamination
2
Power supply
1x9V, ICE 6LR61
Power
consumption
Min. amperage
approx. 31 mA
Max. amperage
approx. 115 mA
Fuse
F 0.5A 500V, 6.3x32mm
Temperature range
Operation
0°C to 40°C, max. rel. humidity 80 % (no condensation)
Storage
-20°C to 60°C, max. rel. humidity 80 % (no condensation)
Height
Max. 2000m
Dimensions (HxWxD)
190mm x 89mm x 42.5mm
Weight
Without battery
approx. 360g
With battery
approx. 420g
7.2 Technical parameters of the receiver
Tracking depth
Tracking depth depends on the material and specific application
Cable search mode
Single-pole use
approx. 0~2m
Multi-pole use
approx. 0~0.5m
Single ring conductor
up to 2.5m
Grid voltage identification
up to 0~0.4m
Display
LCD with function display and column diagram
Power supply
6 x 1.5V AAA, IEC Lr03
Power consumption
Min. amperage
approx. 32 mA
Max. amperage
approx. 89 mA
Temperature range
Operation
0°C to 40°C, max. rel. humidity 80 % (no condensation)
Storage
-20°C to 60°C, max. rel. humidity 80 % (no condensation)
Height
Max. 2000m
Dimensions (HxWxD)
241.5mm x 78mm x 38.5mm
Weight
Without battery
Approx. 280g
With battery
Approx. 350g
8.
Repair and maintenance
1.
If the detector does not appear to be working, first make sure that the batteries have enough power and
the test lead is not defective.
2.
Before sending the detector in for repair, take out the battery, describe the problem, and pack the device
properly in order to prevent damage during shipping. We accept no liability for shipping damage.
3.
There is a fuse in the transmitter. If this is damaged during the warranty period, it can be replaced only be
technical customer service. If it is damaged after the warranty period, replace it with a new fuse of the
same type. The fuse is a fast-melting single metal wire fuse; do not replace it with a slow spiral wire fuse,
since otherwise transmission performance and device safety cannot be ensured.
8.1 Troubleshooting
If the detector is not working property, check the points in the table below:
Malfunction
Points to check
Remedial measures
Device will not
switch on
Is a battery installed?
Install new battery.
Is the battery power too low?
Is the battery polarity correct?
Check the polarity.
Transmitter cannot
identify external
Is the contact bad?
Reconnect lead.
Is the sensor defective?
Replace sensor?