Facility
Requirements
18
Need help? Contact [email protected]
Site Preparation
Manual
AC Cable
The Customer is responsible for providing a power cable with connector to fit gland
type of PG29 or M32 to connect the printer to wall mounted power distribution unit PDU
(Supplied with the printer).
Grounding
The MASSIVIT 1800 printer must be connected to a special ground line in order to protect
the operator and the printer and minimize electrostatic affects.
The following grounding requirements must be fulfilled:
Ground impedance must be less than 0.1 ohms.
Pneumatic Requirements
The supply of compressed air to the Massivit 1800 printer may be by way of a central air
supply system, or with the use of a dedicated air compressor. In either situation, a wall-
mounted air outlet will be required. This should have a quick-coupler fitting and be
located near the MASSIVIT 1800 printer.
Figure 9-MASSIVit 1800 Air line
Air Compressor
Operating Pressure: 6 - 8 bars (88.2 - 117.6 psi) at Minimum of 1.2 liter/min (43 CFM).
Air Dryer
We suggest to customers who have moisture in airline consider installing an air dryer, Air
dryer requirements:
Operating Pressure: 6 - 8 bars (88.2 - 117.6 psi) at Minimum of 1.2 liter/min (43 CFM) Dew
point: 2°C (35.6°F).
A
ir
p
re
ss
ur
e
lin
e Ø1/
2”
W
a
te
r T
ra
p
O
il
Se
par
at
or
Air Dryer
Air compressor
6-
8 B
a
r, 43 C
FM
Summary of Contents for 1800 Series