Site
Requirements
11
Need help? Contact [email protected]
Site Preparation
Manual
Site Requirements
This chapter describes the site preparation required for the MASSIVit 1800 printer
operation.
Unloading Space
A suitable unloading area must be prepared. This area should be easily accessible to
the delivery truck and be of sufficient space to unload the crates in which the printer is
shipped. When planning this area, take into consideration:
Height and width of the entrance to the unloading area
Presence of any ramps or slopes
Height and size of unloading dock (if applicable)
Doors and Hallways Clearances
An unobstructed pathway will be required when moving the crated equipment from
the unloading area to the installation site. Doorways, corridors etc. must be of
sufficient height and width to allow for easy maneuverability.
It is highly recommended that the shipping crate be unpacked as close as possible to
the printer's final location.
Conveying equipment
Unloading and moving the Massivit 1800 printer and components is the responsibility
of the customer only.
Forklift Specifications
The following forklift must be used for unpacking and installing the printer:
Lift capacity: of 5000 [kg] (11023 lb) using 2.2 m extension forks
2 x 2.2m extension forks