Masport F39 Room Sealed Freestanding Gas Fire
9
INSTALLATION
FLUEING ARRANGEMENTS
Vertical Terminations
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable
combinations of straight vertical and offset to vertical runs
with vertical terminations. Maximum two 45
o
elbows.
If the flue is ENCLOSED in a chase (min. size 10" (255mm) x 10"
(255mm)) maintain a 40mm" clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after first sale.
Horizontal Terminations for All Flueing Systems
The shaded areas in the diagram below show all allowable
combinations of vertical runs with horizontal terminations.
Maximum one 90
O
elbow (two 45
o
elbows equal one 90
o
elbow).
LPG and NG:
Residential, Manufactured and Mobile Homes
Installations
The fluing arrangements shown below, have a min. of 75% (flue loss)
efficiency with Fan Off, as required for manufactured homes. (Actual
efficiency may be as high as 85%)
May be installed in Manufactured (Mobile) Homes after first sale.
Flue Restrictor Position
To set the Flue restriction as indicated in the diagram, simply loosen the
screws and push the flue restrictor plate to the correct position. Tighten
the screws.
Flue Restrictor setting at
40 Mj/h
Flue Restrictor setting at
31 Mj/h