Masport Geneva F39-LPG Owners & Installation Manual Download Page 21

Masport F39 Room Sealed Freestanding Gas Fire

21

MAINTENANCE

FAN MAINTENANCE

If your fan requires maintenance or replace-
ment, access to the fan is through the plate on
the rear wall of the firebox.  NOTE: the unit
MUST NOT be operated without the fan
access panel securely in place and cor-
rectly sealed.

If the fan is damaged or needs repair, it
shall be repaired by the manufacturer or
its service agent or similiarily qualified
person to avoid a hazard.

IMPORTANT: These fans collect a lot of

dust from within your home. En-
sure you maintain these fan mo-
tors on a regular basis by vacuum-
ing out the fan squirrel cages,
around the motor, and around the
grills on the back of the stove.

Alternate Fan Access:

If the rear access cover is
accessible, it can be removed
to provide access to the fan.

IMPORTANT

Disconnect power supply

before servicing

WARNING:

Electrical Grounding Instructions

This appliance is equipped with a
three pronged (grounding) plug
for your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle. Do not cut
or remove the grounding prong
from this plug.

7) Tighten side panels nuts using the following

procedure:
a. tighten top & bottom outside corner nuts

(2)

b. tighten inside nuts (3)
c. tighten top & bottom inside corners (2)

8) Tighten the 10 nuts on center glass retainer.

9) Repeat step 7 for other side panel.

10) Replace new gasket by gluing it in place.

11) Install door onto stove and check the seal.

To Remove F39 Fan:

1) Unplug or disconnect power source to

stove.

2) Remove all logs and the rear log support,

then remove the 10 screws holding the
access panel in place.

3) Unclip the black and white wires from the

fan motor.

4)  Open both side doors and gently pull the

flex pipe away from the center, otherwise
the fan can catch on the flex pipe during
installation and tear the pipe. Do not tear or
damage the flex pipe.

5) Lift fan off of the 2 pins, tip back and pull

through firebox opening. Disconnect the
green ground wire from the right side of the
fan as soon as you can reach it.

Replacing F39 Fan:

Reverse the above steps (1 - 5). If necessary
install a new gasket before replacing the fan
access panel.  Make sure the fan wires and the
ground wire are reattached.

Hint for pushing fan down onto pins - rub a bit
of dish soap on the grommet so it will slide more
easily onto the pin. Check to make sure the fan
is seated properly on the pins - try to move the
fan back and forth, there should be no noise,
if there is check that the grommets haven't
come loose.

Summary of Contents for Geneva F39-LPG

Page 1: ...r FORYOURSAFETY Donotstoreorusegasolineorotherflamma ble vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorized installer servic...

Page 2: ...ovide you with all the warmth and charm of a woodstove at the flick of a switch The models F39 NG and F39 LPGofthisserieshasbeenapprovedbyAGAforbothsafetyandefficiency Asitalsobearsourownmark it promi...

Page 3: ...Installation Important Message 5 Specifications 5 Before You Start 5 General Safety Information 5 Installation Checklist 6 Clearances to Combustibles 6 Locating Your Masport Gas Fire 6 Combustion and...

Page 4: ...om Sealed Freestand ing Gas Stove We have printed a copy of the contents here for your review The data plat is located on the inside of the drop down pedestal door NOTE Masport units are constantly be...

Page 5: ...down to the floor 4 This appliance is Listed for bedroom instal lations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes before installation 5 T...

Page 6: ...led to inspect this appliance annually Make it a practice to have all of your gas appliances checked annually 13 Do not slam shut or strike the glass door 14 Under no circumstances should any solid fu...

Page 7: ...ng installation The location of the termination cap must con form to the requirements in the Exterior Flue Terminal Locations diagram on page 8 Refer to the Masport Flue Kit in structions supplied wit...

Page 8: ...nable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 M...

Page 9: ...Systems The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontal terminations Maximum one 90O elbow two 45o elbows equal one 90o elbow LPG and NG Resident...

Page 10: ...nnec tor and or copper tubing if allowed by local codes Since some municipalities have addi tional local codes it is always best to consult with your local authorities When using copper or flex connec...

Page 11: ...AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude F39 with 40mj F39 NG NG Full open F39 LPG LPG Full open F39 with 31mj F39 N...

Page 12: ...ble 4 Remove and discard the 3 pressure reg ulator mounting screws A pressure regulator tower B and diaphragm C 5 Insure that the rubber gasket D is prop erly positioned and install the new HI LO pres...

Page 13: ...ains Qty Part Description 1 904 390 Burner Orifice 52 LPG 1 918 034 Decal Converted to 30 000 Btu 1 918 033 Instruction Sheet Additional Piece pkg with unit 1 Log Bracket Restrictor 1 Shut off the gas...

Page 14: ...t Pin D 02 46 B 02 56 A 02 65 7 Place the Left Top Log D 02 46 on the pin on Log B 02 56 and on top of the cutout on Log A 02 65 E 02 45 C 02 44 8 Place Front Right Log E 02 45 on the two pins as show...

Page 15: ...adjust them by loosening the latch catch See diagram 3 Diagram 2 Diagram 3 5 Remove the blue plastic protective coating from the glass 6 Test the seal around the door by placing a piece of paper betw...

Page 16: ...utorremovethegroundingprongfromthisplug INSTALLATION WIRING CAUTION Label all wires prior to disconnectionwhenservicingcon trols Wiring errors can cause im proper and dangerous operation This heater d...

Page 17: ...to ON position 4 Turn ON the flame switch During the first few fires a white film may develop on the glass front as part of the curing process The glass should be cleaned or the film will bake on and...

Page 18: ...ot touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbors phone Follow the gas supplier s in structions If you cannot reach your gas suppli...

Page 19: ...e small proba bly yellow flames not coming into proper con tact with the rear of the burner or thermopile WARNING CHILDREN AND ADULTSSHOULDBEALERTEDTO THEHAZARDSOFHIGHSURFACE TEMPERATURE AND SHOULD ST...

Page 20: ...r 7 Put gasket glue on the retainers but do not put glue on the screws Replace the door gasket the two ends butt tight together on the bottom edge of the door 8 Replace door on the stove and check the...

Page 21: ...the following procedure a tighten top bottom outside corner nuts 2 b tighten inside nuts 3 c tighten top bottom inside corners 2 8 Tighten the 10 nuts on center glass retainer 9 Repeat step 7 for oth...

Page 22: ...owing instructions Note Always close off the gas supply before removing the valve 1 Open front pedestal door You may want to put a soft cloth on the base of the unit so that when the pedestal door is...

Page 23: ...1 560242 Side Panel Door Hinge 23 904 258 551891 Side Panel Door Magnet 24 948 255 556074 Door Latch 25 Flex Pipe 3 ID 26 Clamp for Flex Pipe 27 910 233 560065 Fan Auto On Off Thermodisc 28 Mntg Brack...

Page 24: ...nerator Switch c w Wire 66 910 038 Pilot Assy S I T 3 Flame NG 910 039 Pilot Assy S I T 3 Flame LPG 67 PilotHolder 68 W840470 Pilot Assembly Gasket 71 730 528 Log Stand 904 641 556173 Pilot Orifice 50...

Page 25: ...26 Black Mitred Door Complete 730 932 Gold Wrap Door Complete 730 928 Gold Panel Door Complete 101 650 920 560018 Door Gasket Kit 105 Ceramic Paper 106 940 323 P Side Glass 107 936 243 560087 Glass Ga...

Page 26: ...____________________________________________________ ______________________________________________________ _______________________________________________________________ ____________________________...

Page 27: ...nt This Express Warranty Does Not Cover 1 Defects malfunctions or failures caused by incorrect installation normal wear and tear misuse neglect acci dental damage or failure to follow the fuel selecti...

Page 28: ...Printed in Canada Copyright 2004 FPI Fireplace Products International Ltd All rights reserved...

Reviews: