![masosine Certa Plus User Manual Download Page 29](http://html.mh-extra.com/html/masosine/certa-plus/certa-plus_user-manual_1735326029.webp)
19.2 Disassembling the mechanical seal system
To make the procedure clearer, on some pictures the middle housing has been
removed. This is not necessary for regular maintenance.
Removing the seal system
l
Carefully remove the back seal face from the mechanical seal system and store it safely.
The seal face with O-ring at the outer diameter, which is installed in the pump housing.
Removing the spring assembly
l
Remove the spring assembly from the back housing.
m-certa-plus-en-02
29