1.3 Symbology, definitions and manual informations

Those parts of the text not to be ignored are highlighted in bold type preceded by a symbol, as illustrated and
defined below.

 Indicates that particular attention must be paid in order to prevent running  serious risks

which could lead to death or possible harm to the health of personnel.

 A condition which may occur during the lifetime of a product, system or plant considered

at risk regarding damage to persons, property, the environment or economic loss.

 Indicates that particular attention must be paid in order to prevent serious consequences

which could result in damage to tangible goods, such as the resources or the product.

 Instructions of particular importance.

 

Carefully consult this manual before using or carrying out any operation on the generator.

FAILURE TO RESPECT THE SPECIFICATIONS CONTAINED IN THIS USE AND MAINTENANCE MANUAL

WILL RESULT IN FORFEITURE OF THE GUARANTEE ON THE PRODUCT.

This manual was drawn up by the manufacturer and forms an integral part of the generator equipment, definition used
as indicated in Directive 98/37/ EC; the information contained in the manual is addressed to all the persons involved
in the operating life cycle of the generator, and is necessary to inform both those who effectively carry out the different
operations and those who coordinate the activities, to arrange the necessary logistics and to regulate access to the
place where the generator will be installed and operated.

This manual was drawn up by the manufacturer with the purpose of providing essential information and instructions
for proper use and maintenance in conditions of safety. It constitutes an integral part of the generator equipment and
must carefully be protected from any agent which may damage it for the entire life cycle of the generator. The manual
must accompany the generator if transferred to another user or owner.

The manual defines the purpose for which the generator was constructed and contains all the information necessary
to guarantee safe and proper use.
Constant observance of the instructions contained in this manual guarantees the safety of the operator, protection
against damage to persons or things, operating economy and a longer life of the generator.

The drawings are provided by way of example.   Even if the generator in your possession differs from the illustrations
contained in this manual in elements of little significance, for example the colour, the safety of the generator and
the information provided are nevertheless guaranteed.

To facilitate consultation, it has been divided into sections identifying the main concepts;  for a quick look at the
topics, consult the index.

Ongoing improvement and development of the product may have led to modifications to the generator which are not
included in this publication.

Whenever a problem concerning the generator or this publication arises, consult with Mase Generators
SPA for the latest information available.

Summary of Contents for FM 5.4H

Page 1: ...FM 7 5H REV 10 A A 19 05 2006 cod 41822 GRUPPO ELETTROGENO MANUALE DI USO E MANUTENZIONE I Tipo modello N matricola Codice GENSET USE AND MAINTENANCE MANUAL GB ELEKTROAGGREGAT GEBRAUCHSANWEISUNG UND W...

Page 2: ...FM 5 0 H 5 4 H 7 5 H 8 0 H 2 F E L I H M G N Fig 1 D C A B Fig A...

Page 3: ...FM 5 0 H 5 4 H 7 5 H 8 0 H 3 4 1 2 3 3 4 2 1 Fig 2 Fig 3 Fig 4...

Page 4: ...H 5 4 H 7 5 H 8 0 H 4 S A E Service Grade 30 20 10 0 10 20 30 40 Ambient temperature o C 40 20W 20W40 20 30 5W 5W30 10W 10W30 FM 50 H FM 80 H FM 5 4 H FM 7 5 H Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 MA...

Page 5: ...FM 5 0 H 5 4 H 7 5 H 8 0 H 5 FM 5 4 H MECC ALTE Fig 11 Cod 45248 1 8 7 6 4 5 2 3 9 15 14 11 12 13...

Page 6: ...FM 5 0 H 5 4 H 7 5 H 8 0 H 6 FM 7 5 H MECC ALTE Fig 12 Cod 45247 1 8 7 6 4 5 2 3 9 15 14 11 12 13...

Page 7: ...FM 5 0 H 5 4 H 7 5 H 8 0 H 7 FM 80 H MECC ALTE Fig 13 Cod 45236 1 8 7 4 5 6 9 10 11 3 12 13...

Page 8: ...FM 5 0 H 5 4 H 7 5 H 8 0 H 8 FM 50 H MECC ALTE Fig 14 Cod 45235 1 8 7 5 2 3 9 11 12 10 6 13...

Page 9: ...FM 5 0 H 5 4 H 7 5 H 8 0 H 9 FM 50 H Nuova Saccardo Fig 15 Cod 45631 1 8 7 6 5 3 2 14 12 11 10 9 13...

Page 10: ...FM 5 0 H 5 4 H 7 5 H 8 0 H 10 FM 50 H Nuova Saccardo Cod 45629 Fig 16 1 8 7 6 5 3 2 14 12 11 10 9 13...

Page 11: ...cution 22 1 9 10Dangerresultingfrombadstorage 22 2 Generalcharacteristics 23 2 1 Tableoftechnicalcharacteristics 23 2 2 Noiseemission 24 2 3 Generatorcomposition 25 2 4 Instrumentpanel 25 3 INSTALLATI...

Page 12: ...rtment The generator you have purchased is the fruit of years of experience in the sector and for the modern conception the strong sizing the materials employees the continuous updatings constitutes a...

Page 13: ...matically by differential current effect Skilled person Apersonwithtechnicalknow howorsufficientexperiencetoallowhimtoavoidthedangersinherentinelectricity MASE specialised personnel A person able to e...

Page 14: ...dealer or the manufacturer OnlyMasetechniciansorpersonneltrainedbyMasehavethenecessaryknowledgeofthegeneratorandthespecial equipment as well as the experience to carry out any operation in the most e...

Page 15: ...toarrangethenecessarylogisticsandtoregulateaccesstothe place where the generator will be installed and operated Thismanualwasdrawnupbythemanufacturerwiththepurposeofprovidingessentialinformationandin...

Page 16: ...ety and health protection Machine directive 73 23 EC and subsequent amendments contained in thedirective93 68 EC Guaranteeofsafetyofelectrical material intended for use within certain voltage limits L...

Page 17: ...FM 5 0 H 5 4 H 7 5 H 8 0 H 17 GB GB cod 42112 Fig 14 Cod 42118 Cod 46106 STOP Cod 42350 Cod 42346 Cod 42348 Cod 42349 1 8 Position of safety labels...

Page 18: ...derstand the Use and Maintenance Manual before starting the generator The Mase generator has been designed so as to guarantee safe and reliable operation providedthattheinstructionsarefollowed Otherwi...

Page 19: ...the electrical lines connected These current feedbacks may cause electroconduction to the people working for the electricity company or who come into contact with the lines during the failure Moreove...

Page 20: ...ventthataprocedurenotspecificallyrecommendedneedstobeapplied theuserisresponsibleforassuring that such procedure is safe and does not cause harm to persons The manufacturer declines all responsibility...

Page 21: ...o not smoke during refuelling Refuelling must be carried out with extreme care ensuring that fuel does not overflow from the engine tank respecting the maximum level In the event of fuel spillage from...

Page 22: ...angewetoveralls Insulate all the connectors and detached wires Do not leave the power terminal board of the generator uncovered check that the electrical power and auxiliary serviceconnectionshavebeen...

Page 23: ...ENERAL CHARACTERISTICS L DIMENSION W H WEIGHT 76 Kg 86 Kg 92 Kg 90 Kg DEGREE OF PROTECTION CLASS OF ISOLATION TANK CAPACITY AUTONOMY AT 3 4 LOAD GENERATOR TYPE MAX POWER A C 3500 W 3500 W 4600 W 5600...

Page 24: ...is exposed to the noise Moreover the permitted exposure levels may vary from country to country Nonetheless this information allows the machine user to better evaluate the danger and risk Guaranteed a...

Page 25: ...ree phase outlet EC 400V 16A 3 Single phase outlet EC 230V 16A 2P T 4 Single phase outlet EC 230V 16A 2P T 5 Differential switch 4P 25A 6 Magnetothermal switch 3P 6A 5 4 10A 7 5 7 Magnetothermal switc...

Page 26: ...ration if the engine has not started at the first attempt As soon as the engine has started gradually return the air start lever to the original position Before powering any utility leave the engine t...

Page 27: ...noverload short circuitorpolarityinversionoftheDCoutletterminals the Thermal circuit breaker Fig 8 and10 ref 2 trips interruptingcurrentdelivery Torestorethethermalswitchcontact afterhavingidentifieda...

Page 28: ...ine is supplied with oil for petrol powered engines with viscosity SAE 10W 30 Alwayscheckcorrectviscosityoftheengineoilinrelationtotherangeofambienttemperaturesinwhichthe generator operates as indicat...

Page 29: ...theairfilterevery50hoursofoperation Reducetheintervalsifthegeneratoroperatesinparticularly dustyenvironments On average replace the complete air filter every three cleaning operations Never clean the...

Page 30: ...Instrumentpanel 2 Voltmeter 300V 3 Differential magnetothermal switch 1P N 25A 4 Magnetothermal switch 1P 16A 5 Thermal circuit breaker 15A 6 Battery charger terminals 12V 15A 7 Single phase outlet E...

Page 31: ...the air filter Clean its elements or if necessary replace them Check that the oil level does not exceed the MAX notch Bring it down to the correct level The alternator voltage is too low Check that th...

Page 32: ...thegeneratorindicatedinthetable oftechnicalcharacteristics Paragraph2 1oftheUseandMaintenanceManual insertingtheforksunderthebase at the lower part of the generator For lifting with a crane hook steel...

Page 33: ...liability and performance of the Generator on the condition that The generator is used by persons trained through the use and maintenance manual The installation is carried out according to MASE instr...