FM
MASE
GB
25
1.3 Reference documents
The instructions for use provided with each generator
are made up of a collection of documents of which this
manual represents the General Part.
Normally, the following documents are provided:
a – EEC declaration of conformity
b – Instruction manual for use of the generators (this
manual)
c – Wiring diagrams of the control panels and power
board
d – Engine use and maintenance manual
e – Use and maintenance manual issued by the alternator
manufacturer
f – Any other manuals for the optional accessories
issued by the respective manufacturers
g – List of Mase Service Centres
1.4 Facsimile of EEC declaration of conformity
The generators intended for countries in the European
Community are in conformity with the applicable EEC
Directives (see 1.5).
The generators constructed by MASE in conformity
with the applicable EEC Directives are furnished
with an EEC declaration of conformity (Fig.A)
1.5 Reference regulations and legislative provisions
All the MASE generators are designed and manufactured
in compliance with the legislation in force.
The generator and its components are constructed in
accordance with the following applicable regulations
and directives:
EN 292-1/2
Machine safety regulations. General design
principles.
EN 294
Machine safety regulations. Safety distances to
prevent contact of dangerous parts with the upper limbs.
ISO 3046
Alternate internal-combustion engines.
IEC 34-1
Rotary electric machines.
ISO 8528-1
Alternate current generators driven by
alternate internal-combustion engines.
EN 60204-1 (CEI 44-5)
Machine safety. Electrical
equipment of machines.
EN 60439-1 (CEI 17-13/1)
Assembled protection and
manoeuvring equipment for low voltage (BT panels).
EN50081-1/2
Electromagnetic compatibility. General
regulation on emission – Part 1: Residential, commercial
and light-industry environments. Part 2: Industrial
environment.
EN 50082-1/2
Electromagnetic compatibility. General
regulation on immunity – Part 1: Residential, commercial
and light-industry environments. Part 2: Industrial
environment.
89/392/EEC
and subsequent amendments contained in
the Directives
91/368/EEC, 93/44/EEC and 93/68/EEC
.
Essential machine requirements for safety and health
protection (“Machine” directive).
73/23/EEC
and subsequent amendments contained in
the Directive
93/68/EEC
. Guarantee of safety of electrical
material intended for use within certain voltage limits
(“Low Voltage” directives).
1.6 Marking
The generator identification plate carries all the
identification data in conformity with ISO 8528 and in
accordance with the provisions for EEC marking for
those cases where required. Below is a facsimile of the
identification plate fixed on the control panel of each
generator (Fig. 1).
1.7 Machine identification
See Fig. 1.
1 – Manufacturer
2 – Machine code
3 – Year of construction
4 – Power factor
5 – Declared frequency
6 – Continuous power
7 – Rated voltage
8 – Rated current
9 – Weight
10 – Serial number
1.8 Generator composition
The generators of the FORMULA series are essentially
composed of the following components:
-
Engine air filter (Fig. 2 Ref. 1)
-
Knob for pull-start
-
Petrol-powered internal-combustion engine (Fig. 2
Ref. 3)
-
Terminal for earth connection of generator(Fig. 2
Ref. 4)
-
Alternator unit (Fig. 2 Ref. 5)
-
Instrument and outlet panel (Fig. 2 Ref. 6)
-
Engine exhaust (Fig. 2 Ref. 7)
-
Load-bearing chassis (Fig. 2 Ref. 8)
-
Lifting hook (Fig. 2 Ref. 9)
-
Fuel tank (Fig. 2 Ref. 10)
-
Fuel closing tap (Fig. 2 Ref. 11)
1.9 Instrument panel (Fig. 3)
Each generator is fitted with an instrument panel for the
controls carrying the following components:
1)
Main switch
2)
Single-phase thermal switch
3)
Pilot light
4)
Schuko outlet, 16A 2P+GND
5)
EEC outlet, 16A 230V 2P+GND
6)
DC output terminals
7)
DC thermal switch
8)
Three-phase thermal switch
9)
Differential magnetothermal switch
10)
EEC outlet, 32A 230V 2P+GND
11)
EEC outlet, 16A 400V 3P+GND
The machine code number, the serial number and the
year of construction must always be quoted when
contacting the manufacturer for information, requests
for spare parts, etc.
Summary of Contents for FM 3000 S
Page 3: ...MASE FM 3 1 2 3 4 5 6 7 8 2 9 1 10 1 4 5 6 2 3 8 7 9 10 11...
Page 5: ...MASE FM 5 4 6 1 5 1 2 3 7 1 1 2 3...
Page 6: ...FM MASE F 6 8 4 2 1 1 3...
Page 7: ...MASE FM 7 9 FM 3000 S...
Page 8: ...MASE FM 8 10 FM 5000 S...
Page 9: ...MASE FM 9 11 FM 8000 S...
Page 10: ...MASE FM 10 12 FM 9000 ST...
Page 11: ...MASE FM 11 13 FM 9000 STD...