background image

11

Specific technical data

2115/2116

2015

2215/2216

2415

2515

3015

Input voltage 

 

curr

ent 

 

fr

equenc

y

100 - 240 

VAC

 

max.0.35 A

  

50 - 60 Hz

230 - 240 

VAC

max.0.5 A

 

50 - 60 Hz

100 - 240 

VAC 

max.0.9 A

 

50 - 60 Hz

100 - 240 

VAC 

max.

 1.3 A

 

50 - 60 Hz

10 – 30 

VDC 

 

max 4A

10-30 VDC

max 8A

Max. Output Po

wer

16 W

40 W

35 W

67 W

32 W

67 W

Protection at input

Fuse:

 T1.0 AH 

250 V

,  

5 x 20 mm

Fusible resistor

Fuse:

 T1.6 AH 

250 V

,  

5 x 20 mm

Fuse:

 T2.5 AH 

250 V

 5 x 20 mm

5 A 

fuse 

 

on input ca

ble.

10A fuse 

 

on input ca

ble

Protection against 

ing

ress of w

ater 

 

(IEC 60529)

IP4X

(IP67 a

vailible)

IP3X

IP4X

(IP67 a

vailible)

IP4X

(IP67 a

vailible)

IP4X

(IP67 a

vailible)

IP4X

(IP67 a

vailible)

Insulation Class

Class II

Class II

Class II

Class II

Class III,

  

common minus

Class III,

  

common minus

Dimensions (LxWxH)

90x45x32mm (2115)

103,5x46,8x38,7mm 

(2116)

100x63x47mm

107x67x36,5mm 

(2215)

117x75x44mm (2216)

135x80x44mm

107x67x36,5mm

135x80x44mm

W

eight

125g / 150g

220g

250g

350g

250g

350g

Input ter

minals

- Non-detacha

ble mains cord or 2-pin connector (IEC 60320/C7) f

or detacha

ble mains cord set (2115,

 2215 and 2415 onl

y)

- Exchangea

ble 

AC ada

pters (model 2116 and 2216 onl

y).

 2015 has fixed plug-in connector

- DC/DC chargers 2515 and 3015 has ca

ble in and out.

Summary of Contents for 2015

Page 1: ...TRONICS AS P O Box 177 N 1601 Fredrikstad NORWAY Phone 47 69 36 43 00 Telefax 47 69 36 43 01 E mail sales mascot no Web www mascot no EN User Manual Bruksanvisning Käyttöohjeet Bedienungsanleitung Mode d emploi Manual de instrucciones Istruzioni per l uso Language specific user manuals are available on www mascot no downloads usermanuals ...

Page 2: ...UCE THE RISK OF FIRE AND ELECTRIC SHOCK READ THROUGH THESE INSTRUCTIONS PRIOR TO USING THE PRODUCT CAREFULLY FOLLOW THESE INSTRUCTIONS WHEN USING THE PRODUCT RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE ding to standard EN IEC 60529 but must not be immersed in water for longer periods of time Products marked with the double square symbol are double insulated Insulation Class II Products without ...

Page 3: ... facilitate immediate removal of the products mains supply should an opera tional error occur during use If the product has a detachable mains cord the appliance coupler may be used as a disconnect device The product is switched on by inserting the mains plug into the mains socket and switched off by disconnecting the mains plug from the mains socket The product may be connected to an IT type main...

Page 4: ...healthcare environ ment NOTE Products relying on safety earth for protection Class I may not be used in home healthcare environment unless they are perma nently wired to the building installation Installation must only be carried out by qualified service personnel following the below instructions The protective earth conductor must be min 0 75 mm2 Connect the protective earth conductor to the exte...

Page 5: ...ounted in a vehicle it may only be used when the vehicle is not in use When in use position this product so that the la bel can be read within 40 cm of the operator This charger is a fast charger for NiCd NiMH batteries The standard version utilizes a method called dV detection for charge termination when the batteries are fully charged This method is based on the fact that the voltage drops over ...

Page 6: ...igned for charging NiCd and NiMH batteries only Make sure you have the correct battery charger for the battery you wish to charge The number of cells must correspond to the output indicated on the charger Never charge more battery cells than the charger is made for When charging separate battery cells avoid charging cells with different rest capacities at the same time A new charge cycle starts by...

Page 7: ...the batteries if a dV signal fails to appear during charging It is normal to have a safety timer that is longer than the max charge time Some battery cells may give a voltage drop during the initial part of the charge cycle To avoid interruption of the charge cycle the charger has a start timer that prevents dV detection during the first minutes of the charge cycle The charger is programmed to dis...

Page 8: ...t the battery manufacturer for details If the safety timer runs out before dV is detected the charger will go directly to trickle charge mode no top off charge and LED will be continuously green lf the battery voltage is far below normal the charger will cut the fast charge current and go to trickle charge mode The LED will then indicate error by flickering green and orange light lf the mains inpu...

Page 9: ...ted by an intermittent orange flash while the LED is green The same will take place if the battery temperature exceeds 40 C The current will then remain low until the temperature is at a level where fast charge can start lf the temperature is too high for safe charging 60 C the LED will show error by intermittently flashing orange and green By using the temperature increase control dT dt the charg...

Page 10: ...nnect exchangeable DC output plugs Common technical data NiCd NiMH versions cells in series 3 6 cell 4 8 cell 5 10 cell 6 12 cell 10 20 cell 12 25 cell 15 30 cell No Load Voltage 12 8 V 0 7 V 16 5 V 1 0 V 21 0 V 1 2 V 24 7 V 1 5 V 41 0 V 2 0 V 51 V 2 V 55 V 3 V Min output voltage for ΔV detection 3 7 V 5 0 V 6 2 V 7 5 V 12 5 V 15 V 19 V Max output voltage for ΔV detection 10 8 V 14 4 V 18 0 V 21 6...

Page 11: ...on against ingress of water IEC 60529 IP4X IP67 availible IP3X IP4X IP67 availible IP4X IP67 availible IP4X IP67 availible IP4X IP67 availible Insulation Class Class II Class II Class II Class II Class III common minus Class III common minus Dimensions LxWxH 90x45x32mm 2115 103 5x46 8x38 7mm 2116 100x63x47mm 107x67x36 5mm 2215 117x75x44mm 2216 135x80x44mm 107x67x36 5mm 135x80x44mm Weight 125g 150g...

Page 12: ...0 mA 15 mA 2 2 A 150 mA 330 mA 70 mA 150 mA 50 mA 1 8 A 150 mA 270 mA 70 mA 100 mA 50 mA 3 5 A 300 mA 480 mA 70 mA 100 mA 50 mA 1 8 A 150 mA 270 mA 70 mA 100 mA 50 mA 6 12 cell Fast charge Top off charge Trickle charge 0 7 A 100 mA 100 mA 30 mA 30 mA 15 mA 1 8 A 150 mA 270 mA 60 mA 100 mA 50 mA 1 5 A 100 mA 240 mA 60 mA 100 mA 50 mA 3 0 A 200 mA 420 mA 60 mA 100 mA 50 mA 1 5 A 100 mA 240 mA 60 mA ...

Reviews: