9
•
Advisory specifications for the extension cable:
Power
Extended length m(ft)
220V
0-10
(
0-25
)
10-20
(
26-50
)
20-30
(
51-100
)
30-50
(
101-150
)
380V
0-20
(
0-50
)
20-30
(
51-100
)
30-60
(
101-200
)
60-100
(
201-300
)
Rated Current
mm
2
0-5A
2.5
4.0
6.0
10.0
5A-8.5A
4.0
6.0
10.0
16.0
•
Power on/off the machine
Switch the starter to ON to run the motor, and the rammer begins to work. Switch it to OFF to
stop the machine.
•
Correct compacting operation
1..4 Guide the machine on handle and it will move forward automatically. Never let the
machine works overload.
1..5 Picture b is the correct way to operate the rammer, as the whole base plate makes
parallel punches on the ground. Picture a and c are wrong ways, for it only allows the
front or back part of the plate to tamp the ground. Wrong compacting operations
shorten base plate’s service life.