background image

INSTRUCTION MANUAL

GREEN CONCRETE SAW
MFG10 SERIES

WARNING

!

To reduce the risk of injury, all operators and maintenance personnel must read and understand these 
instructions  before  operating,  changing  accessories,  or  performing  maintenance  on  Masalta  power 
equipment. All  possible  situations  cannot  be  covered  in  these  instructions.  Care  must  be  exercised 
by everyone using, Maintaining or working near this equipment.

R

R

Summary of Contents for MFG10 Series

Page 1: ...aintenance personnel must read and understand these instructions before operating changing accessories or performing maintenance on Masalta power equipment All possible situations cannot be covered in...

Page 2: ...h are not recommended by MASALTA for this equipment Damage to the equipment and or injury to user may result The manufacturer does not assume responsibility for any accident due to equipment modificat...

Page 3: ...mond blades before each use The blade should exhibit no cracks dings or flaws in the steel centered core and or rim Center arbor hole must be undamaged and true Examine blade flanges for damage excess...

Page 4: ...ncy MAINTENANCE SAFETY NEVER lubricate components or attempt service on a running machine ALWAYS allow the machine a proper amount of time to cool before servicing Keep the machinery in running condit...

Page 5: ...ning objects near the machine Shut off the engine before refueling Use only clean filtered unleaded gasoline CAUTION Use only clean filtered gasoline fuel WARNING Hot surface WARNING Always wear heari...

Page 6: ...s top quality components and a committed attention to state of the art manufacturing OPERATING PRINCIPLE The following instructions were compiled to provide you information on how to obtain long and t...

Page 7: ...over to gain access to the diamond blade 6 Use the provided blade nut and blade shaft locking wrenches to install the diamond blade 7 While holding the blade shaft with the locking Wrench remove the b...

Page 8: ...th the blade in the raised position 13 If cutting is complete shut the saw down using the following Shutdown Procedures TO STOP THE ENGINE To stop the engine under normal conditions 1 Place the engine...

Page 9: ...surface feet per minute speed SFPM is approximately 6 000 Blade improperly mounted on arbor shoulders and flanges Ensure blade is properly affixed on the blade shaft Blade does not cut straight and or...

Page 10: ...t circuiting Replace defective spark plug wiring Wrong fuel type Flush fuel system and replace with correct type of fuel Water or dust in fuel system Flush fuel system Air cleaner dirty Clean or repla...

Page 11: ...Replace ignition coil Weak in power compression is proper but misfires Dirty spark plug Clean or replace spark plug Wrong fuel type Flush fuel system and replace with correct type of fuel Spark plug h...

Page 12: ...fuel from spilling 3 Use trolley wheel a for short distance transportation MFG10 3 4 Measured sound power level 88 dB A Guaranteed sound power level 110 dB A SEPECIFICATION Motor MFG10 3 Petrol Robin...

Page 13: ...need of parts or major service be sure to see your dealer For your convenience we have provided this space to record relevant data about your saw These products are covered by warranty for a period of...

Page 14: ...ci n atteste que le mat riel 1 Category Art Categor a Cat gorie Green Concrete Saw 2 Type Typ Tipo Type MFG10 SERIES has been produced in accordance with the following standards in bereinstimmung mit...

Page 15: ...LTA ENGINEERING CO LTD Add Weisi Road Baohe Industrial Estate Hefei 230051 Tel 86 551 4846601 4846580 Fax 86 551 4846616 4846626 E mail sales masalta com cn masalta mail hf ah cn http www masalta com...