background image

                           
 
 
 
 

EC DECLARATION OF CONFORMITY 

 

AT UYGUNLUK BEYANI 

 
 

Manufacturer / İmalatçı 

: MAS DAF MAKİNA SANAYİ A.Ş. 

Address / Adres 

: Aydınlı Mah. Birlik OSB. 1.No’lu Cadde No:17 Tuzla - İSTANBUL / TÜRKİYE

 

Name and address of the person authorised to 
compile the technical file 
Teknik Dosyayı Derleyen Yetkili Kişi ve Adresi 

Vahdettin YIRTMAÇ 
Aydınlı Mah. Birlik OSB. 1.No’lu Cadde No:17  
Tuzla - İSTANBUL / TÜRKİYE 

The  undersigned  Company  certifies  under  its  sole  responsibility  that  the  item  of  equipment  specified  below  satisfies  the 
requirements of the mainly Machinery Directive 2006/42/EC which is apply to it. 
The item of equipment identified below has been subject to internal manufacturing checks with monitoring of the final assessment 
by 

MAS DAF MAKİNA SANAYİ A.Ş. 

Aşağıda  tanımlanmış  olan  ürünler  için  Makine  Emniyeti  yönetmeliği  2006  /  42  /  AT’  nin  uygulanabilen  gerekliliklerinin  yerine 
getirildiğini ve sorumluluğun alınmış olunduğunu beyan ederiz. 
Aşağıda tanımlanan ürünler içüretim kontrollerine bağlı olarak 
MAS DAF MAKİNA SANAYİ A.Ş. tarafından kontrol 
edilmiştir. 

Equipment / Ürün 

:

 

Vertıcal Hıgh Pressure Multıstage Centrıfugal Pumps 

Yüksek Basınçlı Çok Kademeli Düşey Milli Santrifüj Pompalar 

Seri / Model-Tip 

: KMU-V Series – 

KMU-V Serisi

 

 
For pumps supplied with drivers/ 
Elektrikli Pompa Üniteleri Related Directives / Yönetmelikler 
2006/42/EC 

Machinery Directive

 / 2006/42/AT Makine Emniyeti Yönetmeliği 

2014/35/EU 

Low Voltage Directive

 / 2014/35/AB Alçak Gerilim Yönetmeliği 

2014/30/EU 

Electromagnetic Compatibility Directive

 / 2014/30/AB Elektromanyetik Uyumluluk Yönetmeliği 

EUP 2009/ 125 /EC  

Electric Used Products Directive/ 

Elektrik Kullanan Ekipmanlar Direktifi (EUP) 

94/9/EC 

Equipment For Explosive Atmospheres / 

Patlayıcı Ortamlardaki Ekipman Yönetmeliği 

2009/125/EC 

European Ecodesign Directive, Regulation No: 547/2012 Ecodesign Requirements for Water Pumps / 

Avrupa 

Ekotasarım Direktifi, 

 

(SGM-2015/44) 547/2012 No’lu Su Pompalarında Ekotasarım Regülasyonu 

 
Regulations applied acc. to harmonize standards / Uygulanan Uyumlaştırılmış Standartlar 
TS EN ISO 12100:2010, TS EN 809+A1, TS EN 60204-1:2011. 
 

We hereby declare that this equipment is intended to be incorporated into, or assembled with other machinery to constitute relevant 
machinery to comply  with essential health and safety requirements of Directive The  machinery covered by  this declaration  must 
not  be  put  into  service  until  the  relevant  machinery  into  which  it  is  to  be  incorporated  has  been  declared  in  conformity  with 
provisions of the directive. 

Ekipman,  uygun  bir  makina  oluşturmak  amacıyla  diğer  ekipmanlar  ile  birleştirilirken  ya  da  monte  edilirken  gerekli  sağlık  ve 
güvenlik yönetmeliklerine uyulması gerekmektedir. 
Bu bildiri kapsamında yönetmelikte belirtilen bütün hükümler yerine getirilmeden makinanın devreye alınmaması gerekmektedir. 
 
 
Place and date of issue / 

Yer ve Tarih

 

İstanbul, 02.06.2014

 

Name and position of authorized person 

Yetkili Kişinin Adı ve Görevi 

Vahdettin YIRTMAÇ 

  General Manager / Genel Müdür

 

Signature of authorized person 

Yetkili Kişinin İmzası

 

 

Summary of Contents for KMU-V Series

Page 1: ...Revision No 02 June 2018 Vertical High Pressure Multistage Centrifugal Pumps KMU V SERIES KMU V Series ATEX Version OPERATING MANUAL...

Page 2: ...4 35 AB Al ak Gerilim Y netmeli i 2014 30 EU Electromagnetic Compatibility Directive 2014 30 AB Elektromanyetik Uyumluluk Y netmeli i EUP 2009 125 EC Electric Used Products Directive Elektrik Kullanan...

Page 3: ...TY PRECAUTIONS In order to minimize the accidents during the mounting and putting into service of the pump the following rules have to be applied 1 Do not work without taking safety measures relevant...

Page 4: ...mp org Figure 1 Pump Label ATEX Version Pump Label 2 2 Performance Information Actual performance of the pump can be obtained from the order page and or from the test report This information is given...

Page 5: ...cannot touch them Moving components of the pump such as coupling must be covered so that one cannot touch them Those covers must not be dismounted while the pump is running Dangers that results from...

Page 6: ...econdary component in accordance with DIN 740 is used A coupling guard is given in accordance with EN 953 in case of the pump group includes the coupling and chassis Pump can only be run with a coupli...

Page 7: ...sand stone wood piece etc get into the pump Do not take off this gasket until the installation is completed Start the installation of piping from the pump side Do the necessary assembling and welding...

Page 8: ...t coupling other than the original type installed on pumping group 6 5 2 Method of coupling alignment In order to make the alignment of the coupling it is required to have at least two pieces of about...

Page 9: ...g an eye on the amperage open the valve with care regarding that it should not exceed the value indicated on pump s label After opening the valve completely check the pressure from the pump exit manom...

Page 10: ...does not depend on the quality of shaft finishing 8 1 4 Coupling In KMU V type pumps are used rigid coupling 8 1 5 Drive Apply to the operating instructions of the motor manufacturer 8 1 6 Auxiliary C...

Page 11: ...and pump foot Seperate the pump from the installation Before starting to disassemble the pump brand suction discharge and stage casing and mark confronting locations for the purpose of convenience dur...

Page 12: ...tures are high Too much too little or improper lubrication Increase in axial forcing Change the oil decrease or increase its quantity Clean the balance holes on the impeller disc Excessive leakage fro...

Page 13: ...Type 3 4 5 6 7 8 9 10 11 12 13 14 KMU V 25 145 177 209 241 273 305 337 369 401 433 465 497 KMU V 32 145 177 209 241 273 305 337 369 401 433 465 KMU V 40 162 202 242 282 322 362 402 442 KMU V 50 162 2...

Page 14: ...ollowing formula 2 2 allowable maximum actual 2 allowable maximum actual M M F F In here F and M arearithmetic sum of the loads for each flange at the pump level without regard of the algebraic signs...

Page 15: ...nk B Large radius elbow C Minimum slope is 2 cm m D Fittings flanges etc E Non return valve F Foot valve G Suction valve H Reducer Discharge valve J Electrical connection K Insulated cable L Concrete...

Page 16: ...Imbus Bolt 04 Stage Casing 101 Bronze Journal Bearing 341 Imbus Bolt 10 Final Stage Diffuser 102 Shaft Nut 360 Stud 17 Base Plate 210 Key Standard Impeller 380 Setscrew 18 Journal Bearing Cover 211 Ke...

Page 17: ...Mas Grup 15 17 ALTERNATIVE INSTALLATION APPLICATION DT SB SB DT DT SB SB DT 1 2 4 3 SB Suction Below DT Discharge Top No 3 Figure 11 Alternative Installation Application...

Page 18: ...Mas Grup 16 18 KMU V DRAWING FOR DISMANTLING Figure 12 KMU V Drawing For Dismantling...

Page 19: ...ne and Its Correction 6 Figure 7 Angular Misalignment in Vertical Plane and Its Correction 6 Figure 8 KMU V Pump Dimensions Figure 11 Figure 9 Sample Plumbing 13 Figure 10 KMU V Sectional Drawing 14 F...

Page 20: ...17 Tuzla STANBUL T RK YE Tel 90 216 456 47 00 pbx Fax 90 216 455 14 24 Ankara Regional Directorate A a ve ler Mah 1329 Sok No 6 9 ve ler ANKARA TURKEY Tel 90 312 472 81 60 67 Fax 90 312 472 82 51 Fac...

Reviews: