All of the optional programmable settings are found in the Main Menu displayed on the controller
LCD window when the
Enter
key is pressed. Scrolling through the Main Menu pages can be
done by repeated pressing of the
Enter
key, or by turning the
Monitor
knob while holding the
Enter
key (only when the screen cursor is highlighting one of the up/down page arrows). The
menu is arranged in an endless loop, with either direction leading to every page. Turning the
Monitor
knob alone will move the cursor up (CCW) or down (CW), through each programmable
page selection and on to the next page. Pressing the
Enter
key, while a selection is highlighted,
will either change it’s value or advance to another menu selection, depending on the page
displayed. The
Monitor
knob is also used for changing values, and works in an accelerated
mode whenever the
Enter
key is held. Pressing the
Exit
key will always take you back one level
until the operation mode screen is reached.
Levels
Press
Enter
to open the program menu, and turn the
Monitor
knob to get to the
Levels
page
.
Turn the
Monitor
knob to move the cursor to “Inputs 9 & 10” and press
Enter
.
This page is for setting the gain levels for the unbalanced inputs, raising them to match the levels
of the +4dBu balanced inputs. The cursor is located over the first selection, “Lt”, the Left channel
of Stereo Input 9. Turning the
Monitor
knob will increase or decrease the gain level, and
simultaneously change the reference level. Pressing the
Enter
key will move the cursor to the
next selection. The factory default setting is for a gain of 11.8dB and a reference of –10.2dBV,
appropriate for consumer equipment designed to this specification.
Press the
Exit
key to move back to the
Levels
page. Move the cursor to
Outputs
by turning the
Monitor
knob, and press
Enter
.
This page is used when the MonitorMax output is to be calibrated using a pink noise generator
and SPL meter. The procedure involves inserting a +4dBu pink noise source into one input, and
trimming one output until the SPL meter reading matches the target SPL level on the MonitorMax
display. The procedure is repeated for each speaker.
The cursor is located over the first selection; the Left channel of the Main speaker output.
Turning the
Monitor
knob will increase or decrease the attenuation level in 0.1dB increments.
Holding the
Enter
key while turning the
Monitor
knob will change the setting in 1dB increments.
Pressing the
Enter
key will move the cursor to the next selection.
7