10
5. WARRANTY AND LIMITATION OF LIABILITY
This Martindale product is warranted to be free from defects in
material and workmanship under normal use and service. The
warranty period is 2 years and begins on the date of receipt by the
end user. This warranty extends only to the original buyer or end-
user customer, and does not apply to fuses, disposable batteries,
test leads or to any product which, in Martindale’s opinion, has been
misused, altered, neglected, contaminated, or damaged by accident or
abnormal conditions of operation, handling or storage.
Martindale authorised resellers shall extend this warranty on new and
unused products to end-user customers only but have no authority to
extend a greater or different warranty on behalf of Martindale.
Martindale’s warranty obligation is limited, at Martindale’s option, to
refund of the purchase price, free of charge repair, or replacement of
a defective product which is returned to Martindale within the warranty
period.
This warranty is the buyer’s sole and exclusive remedy and is in lieu
of all other warranties, expressed or implied, including but not limited
to any implied warranty of merchantability or fi tness for a particular
purpose. Martindale shall not be liable for any special, indirect,
incidental or consequential damages or losses, including loss of data,
arising from any cause or theory.
Since some jurisdictions do not allow limitation of the term of
an implied warranty, or exclusion or limitation of incidental or
consequential damages, the limitations and exclusions of this warranty
may not apply to every buyer. If any part of any provision of this
warranty is held invalid or unenforceable by a court or other decision-
maker of competent jurisdiction, such holding will not affect the validity
or enforceability of any other provision or other part of that provision.
Nothing in this statement reduces your statutory rights.
PC15250 instructions rev3.indd 2
09/07/2013 08:25:32
Speci cation
PC15250 Mk2
Phase Sequence Indicator
Electrical
Input voltage range: 50V to 600V AC (Phase to Phase)
Input frequency: 40 to 60Hz
Input current: < 3mA
Environmental
Temperature (Operating & Storage): -10°C to 55°C
Humidity (Operating & Storage):
d
85% R.H
Altitude: up to 2000m
Pollution Degree: 2
General
Power: from circuit under test
Fuses: 600V 0.5A 50kA HRC rated fuses (6x32mm) x 3, one in each probe
Dimensions: 116(L) x 69(W) x 25(D) mm
Weight packed: 361g approx
Includes: instructions
Safety
Conforms to GS38 & BS EN61557-7, CAT IV 600V
Class II, Double Insulation
EMC
Conforms to BS EN61326-2-2
PC15250 instructions rev3.indd 4
09/07/2013 08:25:31
PC15250 instructions rev3.indd 5
09/07/2013 08:25:32
Check out what else you can get from Martindale:
Martindale Electric Company Limited
Metrohm House, Penfold Trading Estate, Imperial Way, Watford WD24 4YY, UK
Tel: +44(0)1923 441717 Fax: +44 (0)1923 446900
E-mail: [email protected]
Website: www.martindale-electric.co.uk
© 2013 Martindale Electric Company Ltd.
Registered in England No. 3387451. E. & O.E. Document Rev3 LITPC15250
•
17th Edition Testers
•
Accessories
•
Calibration Equipment
•
Continuity Testers
•
Electricians’ Kits
•
Environmental Products
•
Full Calibration & Repair Service
•
Fuse Finders
•
Digital Clamp Meters
•
Digital Multimeters
•
Labels
•
Microwave Leakage Detectors
•
Motor Maintenance Equipment
•
Multifunction Testers
•
Non-trip Loop Testers
•
Pat Testers & Accessories
•
Phase Rotation Testers
•
Proving Units
•
Socket Testers
•
Thermometers & Probes
•
Test Leads
•
Voltage Indicators
•
Specialist Metrohm Testers (4 & 5kV)
•
Specialist Drummond Testers
PC15250 instructions rev3.indd 1
09/07/2013 08:25:10