RUSH™ MH10 Beam FX User Manual
15
Linking fixtures to power in a chain
The mains power input cable supplied with the fixture is rated 6 A and can
safely supply enough power for one fixture only. If you want to use the MAINS
OUT socket on the fixture to link power to another fixture in a daisy-chain, you
must obtain the larger power input cables and power link cables available as
an accessory from Martin (see
‘Included Items
Power cable, 1.5 m (4.9 ft.) 18AWG/0.75mm
2
without mains plug
Omega bracket for rigging clamp attachment
Accessories
’ on page 49).
Using the 14 AWG or 1.5mm
2
cables from Martin®, you can link:
Maximum nine (9) MH 10 fixtures in total at 100-120 V, or
Maximum nineteen (19) MH 10 fixtures in total at 200-240 V.
If you install a power plug on the 14 AWG / 1.5 mm
2
power input cable, install
a grounding type (earthed) plug with integral cable grip that is rated 16 A
minimum, 250 V.