Clearance above grade, veranda, porch,
deck, or balcony
Clearance to window or door that may be
opened
Clearance to permanently closed window
Vertical clearance to ventilated soffit lo-
cated above the terminal within a horizon-
tal distance of 2 feet (61 cm) from the cen-
ter line of the terminal
Clearance to unventilated soffit
Clearance to outside corner
Clearance to inside corner
Clearance to each side of center line ex-
tended above meter/regulator assembly
Clearance to service regulator vent outlet
Clearance to nonmechanical air supply in-
let to building or the combustion air inlet to
any other appliance
Clearance to a mechanical air supply inlet
Clearance above paved sidewalk or paved
driveway located on publis property
Clearance under veranda, porch, deck, or
balcony
=
A
=
B
=
C
=
D =
=
E =
E
=
F =
F
=
G =
=
H =
=
I I I
=
J =
J
J
=
K =
K
=
L =
L
=
M=
=
12 inches (30 cm)
6 inches (15 cm) for appliance < 10,000 BTU/hr
(3 kW), 12 inches (30 cm) for appliance > 10,000
BTU/hr (3 kW) and <100,000 BTU/hr (30 kW),
36 inches (91 cm) for appliance > 100,000 BTU/
hr (30 kW)
*
*
*
*
*
3 feet (91 cm) within a height of 15 feet (4.5 m)
above the meter/regulator assembly
3 feet (91 cm)
6 inches (15 cm) for appliance < 10,000 BTU/hr
(3kW), 12 inches (30 cm) for appliance > 10,000
BTU/hr (3kW) and < 100,000 BTU/hr (30 kW),
36 inches (91 cm) for appliance > 100,000 BTU/
hr (30 kW)
6 feet (1.83 m)
7 feet (2.13 m) †
12 inches (30 cm) ‡
12 inches (30 cm)
6 inches (15 cm) for appliance < 10,000 BTU/hr
(3 kW), 9 inches (23 cm) for appliance > 10,000
BTU/hr (3 kW) and < 50,000 BTU/hr (15 kW), 12
inches (30 cm) for appliance > 50,000 BTU/hr
(15 kW)
*
*
*
*
*
*
*
6 inches (15 cm) for appliance < 10,000 BTU/hr
(3kW), 9 inches (23 cm) for appliance > 10,000
BTU/hr (3kW) and < 50,000 BTU/hr (15 kW), 12
inches (30 cm) for appliance > 50,000 BTU/hr
(15 kW)
3 feet (91 cm) above if within 10 feet (3 m)
horizontally
*
*
Canadian Installation
1
US Installation
2
1 In accordance with the current
CSA B149.1
, Natural Gas and Propane Installation Code
.
2 In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
.
† A vent shall not terminate directly above a paved sidewalk or paved driveway that is located between two single family dwellings
and serve both dwellings.
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
* For clearances not specified in
ANSI Z223.1/NFPA 54 or CSA B149.1
, one of the following shall be indicated.
(a) A minimum clearances valve determined by testing in accordance with section 2.19.6, or ;
(b) A reference to the following footnote:
“ Clearance in accordance with local installation codes and the requirements of the gas supplier.”
11
VENTILATION INSTALLATION continued
VENT TERMINAL
AIR SUPPLY INLET
AREA WHERE TERMINAL IS NOT PERMIETTED
X
V
Summary of Contents for MDV12N
Page 15: ...15 Fig 5 Fig 7 Fig 6 Correct Flame Pattern Correct Flame Pattern Incorrect Flame Pattern...
Page 16: ...16 PARTS LIST MDV8 NATURAL 118 PROPANE 85 P ITEM DESCRIPTION QTY...
Page 17: ...17 PARTS LIST MDV12 MDV12V View NATURAL 137 PROPANE 104 P DESCRIPTION ITEM QTY...
Page 18: ...NATURAL 178 PROPANE 131 P ITEM DESCRIPTION QTY PARTS LIST MDV20 MDV20V View 18...