Shields, lenses or ultraviolet screens shall be changed if they become 
visibly damaged to the extent that their effectiveness is impaired, for 
example, by cracks or deep scratches.

The lamp shall be changed if it becomes damaged or thermally deformed.

If the external power cord of this luminaire is damaged, it shall be 
replaced by a special cord exclusively available from your Martin dealer.

A v o i d i n g   e l e c t r i c   s h o c k s

Warning

Always disconnect from mains power before replacing the 
lamp, fuses, or any part, and when not in use. 

• Before operation ensure that factory setting of voltage and frequency 

match local power supply.

• Always ground (earth) the fixture electrically. 
• Use only a source of AC power that complies with local building and 

electrical codes and has both overload and ground-fault protection. 

• Do not expose the fixture to rain or moisture. 
• Never operate the fixture with missing or damaged lenses and/or covers. 

P r o t e c t i n g   y o u r s e l f   a n d   o t h e r s   f r o m   b u r n s   a n d   f i r e

Warning

Hot lamp. The exterior of the fixture can become hot. Allow to 
cool for at least 20 minutes before handling or opening.

• Surface temperature under steady state condition = 100°C (212° F).
• Minimum distance to flammable material = 0.3 m (1 ft).
• Minimum distance to illuminated surface 1.0 m (3.3 ft).
• Never attempt to bypass the thermostatic switch or fuses. Always replace 

defective fuses with ones of the specified type and rating.

• Ensure that the air flow through vents is free and unobstructed.
• Provide a minimum clearance of 0.1 meters (4 inches) around air vents. 
• Never place filters or other materials over the lens or in the optical path. 
• The exterior of the fixture can become hot. Allow the fixture to cool for at 

least 20 minutes before handling. 

• Do not operate the fixture if the ambient temperature (T

a

) exceeds 40° C 

(104° F). 

• Do not stare directly into the light.
• Never operate the fixture without all lenses and covers installed: an 

unshielded lamp emits dangerous UV radiation that can cause burns and 
eye damage.

Summary of Contents for Mania EF1i

Page 1: ...Mania EF1i user manual...

Page 2: ...142 290 250 13 2003 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S...

Page 3: ...Mania EF1i overview 6 Installation 7 AC power 7 Overhead mounting 8 Operation 10 Setting the trig mode 10 The gobo wheel 11 Focusing the Mania EF1i 12 Basic service 13 Cleaning 13 Lamp maintenance 14...

Page 4: ...ollow the safety precautions listed below and observe all warnings in this manual and printed on the fixture If you have questions about how to operate the fixture safely please contact a Martin distr...

Page 5: ...ssing or damaged lenses and or covers Protecting yourself and others from burns and fire Warning Hot lamp The exterior of the fixture can become hot Allow to cool for at least 20 minutes before handli...

Page 6: ...hment such as a safety cable Block access below the work area whenever installing or removing the fixture UNPACKING The packing material is carefully designed to protect the fixture during shipment al...

Page 7: ...external power cord of this luminaire is damaged it shall be replaced by a special cord exclusively available from your Martin dealer Configuring for local mains power The Mania EF1i has a switch sel...

Page 8: ...ectrician if you have any doubts about proper installation Following the cord cap manufacturer s instructions connect the appropriate wires to ground earth live and neutral The following table below s...

Page 9: ...rough the clamp hole in the mounting bracket 3 If permanently installing the fixture verify that the hardware not included and mounting surface can bear at least 10 times the fixture s weight 4 Workin...

Page 10: ...Use the switch on the back of the fixture to set it to Auto or Music trig mode In Auto Trig mode trigger signals are generated randomly This will result in unsynchronized operation that is not in tim...

Page 11: ...on switch The wheel will stop when the switch is set to O In Auto trig mode the wheel will rotate when switch is in position I or II In Music trig mode the wheel will react to the beat of the music in...

Page 12: ...FOCUSING THE MANIA EF1I The focus is adjusted using the mechanism next to the lens This is easiest to do in Music Trig mode while no music is being played Pull the mechanism out or push it in until a...

Page 13: ...es overheating and damage to the fixture that is not covered by the warranty Cleaning the air vents To maintain adequate cooling dust must be cleaned from the air vents periodically Remove dust from t...

Page 14: ...surface lift the particles off with a soft repeated press 6 Remove smoke and other residues with cotton swabs or unscented tissues moistened with isopropyl alcohol A commercial glass cleaner may be us...

Page 15: ...y damage the fixture Installing a lamp in the Mania EF1i 1 Disconnect the fixture from power and allow it to cool for 20 minutes 2 Remove the thumb screw holding the cover in place 3 Slide the fixture...

Page 16: ...snaps into place 9 Close the fixture cover and tighten the thumb screw MAINS FUSE The Mania EF1i uses a time delay fuse for protection against current overload An indication that the fuse may have bl...

Page 17: ...next to the mains power connector with a flat head screwdriver and remove the fuse 3 Replace the fuse with one of the same type The fuse rating is listed on the serial number label and in Specificatio...

Page 18: ...ed on but does not light then check and replace fuse if necessary Burned out lamp Install new lamp Fixture to hot Allow to cool Improve air flow around fixture No action Sound too low to activate cont...

Page 19: ...m distance to illuminated surface 1 0 m 3 3ft Minimum clearance around air vents 0 1 m 4in C ON T R O L A N D P R O G R A M M I N G Stand alone triggers music or auto E L E C T R I C A L Input 3 prong...

Page 20: ...tor 3 m 9 8 ft EU mains cable 3x1 0mm2 with no male connector Philips 12V EFP 8H 100W lamp User manual A C C E S SO R I E S Philips 12V EFP 8H 100W lamp P N 97000004 Half coupler clamp P N 91602005 Fu...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...www martin dk Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Reviews: