Martin Engineering M4097-05/18
5
Martin
®
Air Cannon Controller - multiple circuit
Figure 2. Terminal Block Layout
Wiring air cannon
solenoids to
controller
NOTE
Only wiring required is power wire to controller and
N terminals on controller’s printed terminal strip.
1. Connect wires from air cannon solenoids to terminal strip outputs 1
through 10 and N terminals (see Figure 2). Connect number 1 solenoid to
1 supply and N, number 2 solenoid to 2 supply and N, etc. Continue until
all solenoids are connected.
2. Connect ground wire from each solenoid to controller enclosure. Route
power wire (115 VAC, 60 Hz) into controller enclosure.
3. Connect power safety ground wire to terminal block labeled GND.
4. Connect power wires to terminal blocks labeled 110V and COM. Connect
phase to 110V and neutral to COM.
5. Ensure ENABLE jumper is in place.
Fuse
Solenoid
Ground
Terminals
Input Power
Terminals
TERMINAL BLOCK NOTES:
1) ACTUAL COUNT OF COMMON TERMINALS
MAY BE LESS THAN SHOWN.
2)UNMARKED TERMINALS DO NOT REPRESENT
ACTUAL COUNT OF UNUSED SPARES.
Terminals
ENABLE
Jumper Wire
Installation