Installing Power Supply Units
39
3. See ”Installing a cable in a cable gland” on page 23. Pass the hybrid
output cable through the cable gland marked
DMX/RDM +Power #1
on the PSU.
4. See Figure 15. Connect the wires from the hybrid Splitter cable to the
terminals marked
OUTPUT #1
in the PSU as follows:
• Connect the braided copper and/or foil shield data ground/common
conductor to the terminal marked
GND
.
• Connect the red data +ve (hot) wire to the terminal marked
DMX+
.
• Connect the green data -ve (cold) wire to the terminal marked
DMX-
• Connect the white 30 V +ve (hot) wire to the terminal marked
+U
.
• Connect the black 30 V -ve (cold) wire to the terminal marked
-U
.
5. Tighten the cable gland as described in ”Installing a cable in a cable
Figure 15: Hybrid Splitter cable pinout in PSU
HYBRID SPLITTER CABLE PINOUT
Wire
Function
Terminal
White
+30 VDC
+U
Black
-30 VDC
-U
Shield
Data shield
DMX GND
Green
Data -ve
DMX-
Red
Data +ve
DMX+
HYBRID SPLITTER CABLE PINOUT
Wire
Function
Terminal
White
+30 VDC
+U
Black
-30 VDC
-U
Shield
Data shield
DMX GND
Green
Data -ve
DMX-
Red
Data +ve
DMX+