34
Martin Professional™ Exterior 50 & 100™ system user manual
after the 16 amps maximum limit is reached, you must create a new
chain of PSUs that has its own connection to a building installation AC
mains power circuit.
Connecting a PSU to DMX control data
To connect the Exterior 50 & 100 PSU to DMX control data:
1. Check that the system is isolated from AC mains power and that
power cannot be reapplied during work on the system.
2. See Figure 11. Prepare the data input cable for connection to the PSU
by stripping the last 60 mm (2.4 ins.) of the outer cable jacket. Strip the
last 10 mm (0.4 ins.) of the data ground/common, the data +ve (hot)
and data -ve (cold) wires. The use of ferrules (I-type end caps) is
recommended.
Figure 11: Control data input connections in PSU
Preparation of DMX
data cable
60
DMX data
IN/OUT 1
DMX data
IN/OUT 2