background image

24

EvenLED user manual

Service and maintenance

DANGER! Read “Safety Information” on page 3 before carrying out service or maintenance work on 
the EvenLED. Disconnect the panel from power before cleaning.

Important! The EvenLED requires periodic cleaning to maintain reliable operation and protect the 
investment it represents. Excessive dirt and particle buildup degrades performance, causes 
overheating and may cause damage that is not covered by the product warranty.

The user will need to carry out periodic cleaning, and it is also possible for the user to update the EvenLED 
software using the Martin EvenLED Software Uploader device. All other service operations must be carried 
out by Martin Professional or its approved service agents.

Installation, on-site service and maintenance can be provided worldwide by the Martin Professional Global 
Service organization and its approved agents, giving owners access to Martin’s expertise and product 
knowledge in a partnership that will ensure the highest level of performance throughout the product’s 
lifetime. Please contact your Martin supplier for details.

It is Martin policy to apply the strictest possible calibration procedures and use the best quality materials 
available to ensure optimum performance and the longest possible component lifetimes. However, LEDs are 
subject to wear and tear over the life of the product, resulting in gradual changes in color and overall 
brightness over many thousands of hours of use. The extent of wear and tear depends heavily on operating 
conditions and environment, so it is impossible to specify precisely whether and to what extent LED 
performance will be affected. However, you may eventually need to ask Martin Professional to replace LEDs 
if their characteristics are affected by wear and tear after an extended period of use and if you require 
panels to perform within very precise optical and color parameters.

Cleaning

Regular cleaning is essential for product life and performance. Buildup of dust and dirt degrades the panel’s 
light output and cooling ability.     

Cleaning schedules will vary greatly depending on the operating environment. It is therefore impossible to 
specify precise cleaning intervals for the EvenLED. Inspect panels within their first few weeks of operation to 
see whether cleaning is necessary. Check again at frequent intervals. This procedure will allow you to 
assess cleaning requirements in your particular situation. If in doubt, consult your Martin dealer about a 
suitable maintenance schedule.

Warning! Disconnect from power before cleaning. Do not allow the product to become wet. Take 
care not to damage wiring.

Important! Do not use abrasives, solvents or caustic cleaning products for cleaning.

The EvenLED’s aluminum housing can be cleaned with a cloth that is slightly dampened – but not wet – with 
a solution of water and a mild detergent such as car shampoo. To clean the housing:

1. Isolate the panel from AC power and allow it to cool for 20 minutes.

2. Gently wipe away dirt and dust with the damp cloth.

3. Allow any moisture to dry before reconnecting to power.

Software installation

It may be necessary to upload new software (firmware) to the EvenLED if you believe that the product has a 
software-related fault or if you want to update to a newer version. Software updates are available from the 
Martin website (http://www.martin.com) and can be installed via the DMX data link with the EvenLED 
Software Uploader, available from Martin (P/N 90758097). See the separate EvenLED Software Uploader 
user manual for details.

Summary of Contents for EvenLED RGB LED Panel

Page 1: ...EvenLED RGB LED Panel User Manual TM...

Page 2: ...t loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The Martin logo the Martin name and all other...

Page 3: ...A on 1 888 tech 180 P R O T E C T I O N F R O M E L E C T R I C S H O C K Connect the product to AC mains power within the range 100 240 V nominal at 50 or 60 Hz only Disconnect the entire installatio...

Page 4: ...only If you relay power from one panel to another using POWER THROUGH sockets do not connect more than 9 panels in total to each other in an interconnected chain if AC mains power is 100 120 V 50 60...

Page 5: ...e system 14 Connectors overview 14 AC power 15 Connecting to power 16 Relaying power between panels 16 Current overload safety 17 Connecting the DMX control data link 17 Connection pinouts 17 Making d...

Page 6: ...n com Comments or suggestions regarding this document may be e mailed to service martin dk or posted to Service Department Martin Professional A S Olof Palmes All 18 DK 8200 Aarhus N Denmark Unpacking...

Page 7: ...achments that can hold a static load at least ten times heavier than the total weight they must secure and are approved for this weight by a technical standards organization such as T V Warning Mainta...

Page 8: ...ED system 1 Check that the pipe or truss onto which you are mounting the EvenLED system is horizontal 2 See Figure 2 Loosen the clamp position locking rings 3 and slide the clamps 1 as wide apart as p...

Page 9: ...ough the top handle 14 of the frame 9 Connect DMX and power cables Adding panels vertically To add panels underneath the first panel 1 See Figure 3 on page 9 Loosen the panel to panel locking knob 9 a...

Page 10: ...s 1 to 4 above Check that all safety wires are attached exactly as shown in Figure 6 and described above Adding panels horizontally To add a panel beside a panel that is already installed 1 Suspend th...

Page 11: ...ond to commands it receives on channels starting at channel 1 the DMX signal at the first panel s DMX OUT output is processed by subtracting 96 channels and re addressing the commands sent from the co...

Page 12: ...on page 11 and see examples in Figure 8 Do not connect more than 32 devices in one chain on a DMX512 link without using a splitter amplifier Do not split a DMX link with a passive Y connector Branchi...

Page 13: ...t limitations Refer to AC power on page 15 for details of establishing power circuits Figure 8 System layouts A Individual control Panels respond to different commands sent to different DMX addresses...

Page 14: ...el but use this output for grouped DMX control of panels in which panels share the same DMX address respond to the same DMX commands and behave identically Power connectors The blue Neutrik PowerCon P...

Page 15: ...t accidental reconnection during service and each power distribution circuit must be dimensioned to safely handle a current of 20 A for each chain of EvenLED panels connected to it Important Do not co...

Page 16: ...t the yellow green wire to ground earth Connect the blue wire to neutral Connect the brown wire to live 4 Check that all installation work is completed and carry out appropriate tests and safety check...

Page 17: ...If a panel shuts down although it is correctly connected to power this circuit may have been activated by a fault Disconnect the panel from power and contact your Martin supplier for assistance If the...

Page 18: ...See System layouts on page 13 for diagrams of possible installations To connect a panel to the data link 1 Connect the DMX data output from the controller to the EvenLED s DMX IN male XLR socket 2 Ru...

Page 19: ...sing a standard DMX 512 controller 16 and 8 bit DMX control modes The EvenLED panel is designed to be used with 16 bit control per color This ensure smooth and step free operation and requires 96 DMX...

Page 20: ...ottom two rows simply repeat the number displayed on the top two rows Software version display example See Figure 14 If a panel is running software version 29 20 LED 15 lights in the top row 1 and 8 L...

Page 21: ...on Step 1 and while you check panel mode settings Step 9 but steps 2 to 8 must change to the next step at 1 second intervals You only change DMX values for the red LEDs in each step The green and blue...

Page 22: ...tep 5 During steps 6 to 8 panels indicate which mode settings they are acquiring by lighting LEDs red or green as shown in Figure 15 on page 21 If you send an Ignore value for a mode setting that you...

Page 23: ...lue Hex value Setting Panel configuration enable Step 1 Reds1 20 46 56 Hold this value at power on Greens and blues2 50 122 132 Hold this value at power on and throughout the rest of the procedure Sta...

Page 24: ...ou may eventually need to ask Martin Professional to replace LEDs if their characteristics are affected by wear and tear after an extended period of use and if you require panels to perform within ver...

Page 25: ...orrect use of DMX OUT and DMX THROUGH connectors Check number of channels required by panels in one chain does not exceed 512 if individual control is required Incorrect mode setting Check panels are...

Page 26: ...mm 9 8 in Pixels per m2 16 Color resolution 16 bits per color Viewing angle 112 56 56 Minimum LED source lifetime to 70 of initial output level 40 000 hours at full intensity C o ns t ru c tio n Pane...

Page 27: ...power input cable with PowerCon input connector P N 11541503 User manual P N 35000222 A cc e ss o r ies Neutrik PowerCon NAC3FCA power input connector cable mount blue P N 05342804 Neutrik PowerCon NA...

Page 28: ...an Parliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Reviews: