EvenLED user manual

Cable and link layout details

EvenLED panels are controlled via the lighting industry standard DMX512 serial data protocol. Installations 
must follow the standard recommended practices for DMX512. The key points to respect are:

• Use DMX512-compliant cable. Such cables have one or more twisted pairs with nominal characteristic 

impedance 120 ohms and low capacitance. Single-pair DMX512 cable is suitable for EvenLED panels 
because they do not use pins 4 and 5 of the DMX connection. The minimum recommended wire size is 
0.25 mm

2

 (24 AWG) for runs up to 300 meters (1000 ft.) and 0.32 mm

2

 (22 AWG) for runs up 500 meters 

(1640 ft).

• Do not use microphone cable. It does not have the correct characteristics and may cause erratic behavior 

of the system.

• Shielded (STP) or unshielded (UTP) CAT 5 network cable can be used in fixed installations. For further 

information see: http://www.esta.org/tsp/working_groups/CP/DMXoverCat5.htm

• Panels must be ‘daisy-chained’ (i.e. the control data cable must be connected in one single chain of 

panels). It is possible to split a link into two branches by using the DMX THROUGH and DMX OUT 
outputs from one panel at the same time, but note that these outputs relay the DMX signal differently (see 
“Grouped and independent panel control” on page 11 and see examples in Figure 8).

• Do not connect more than 32 devices in one chain on a DMX512 link without using a splitter-amplifier. 

• Do not split a DMX link with a passive “Y” connector. Branching the link with a “Y” will create multiple data 

reflections that can block or degrade signal transmission.

• Use a dedicated DMX512 splitter-amplifier such as the Martin RS-485 Opto-Splitter™ (P/N 90758060) to 

extend the chain beyond 32 devices or split it into two or more branches. 

• Terminate each chain on the link with a 120 ohm resistor (available from Martin, P/N 04150308) across 

the data hot (+) and cold (-) conductors (pins 2 and 3 on a 5-pin XLR connector) at the output of the last 
panel on the chain.

• Avoid long parallel runs of AC power and control data cables, as these may cause interference on the 

data link.

Mixing EvenLED panels and other types of fixture on a DMX link

Mixing EvenLED panels and other types of lighting fixture on one DMX link is possible but if you add the 
lighting fixture in the middle of the link, address-setting is complex and is therefore not covered in detail in 
this manual.

If you need to add a different type of lighting fixture to a link with EvenLED panels, it is easiest to add it at 
the end of the link using the last EvenLED panel’s DMX OUT connector. The fixture must be set to DMX 
address 001, and the controller must send commands to the fixture at the next available address after the 
DMX channels used by the last panel on the link.

Summary of Contents for EvenLED RGB LED Panel

Page 1: ...EvenLED RGB LED Panel User Manual TM...

Page 2: ...t loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The Martin logo the Martin name and all other...

Page 3: ...A on 1 888 tech 180 P R O T E C T I O N F R O M E L E C T R I C S H O C K Connect the product to AC mains power within the range 100 240 V nominal at 50 or 60 Hz only Disconnect the entire installatio...

Page 4: ...only If you relay power from one panel to another using POWER THROUGH sockets do not connect more than 9 panels in total to each other in an interconnected chain if AC mains power is 100 120 V 50 60...

Page 5: ...e system 14 Connectors overview 14 AC power 15 Connecting to power 16 Relaying power between panels 16 Current overload safety 17 Connecting the DMX control data link 17 Connection pinouts 17 Making d...

Page 6: ...n com Comments or suggestions regarding this document may be e mailed to service martin dk or posted to Service Department Martin Professional A S Olof Palmes All 18 DK 8200 Aarhus N Denmark Unpacking...

Page 7: ...achments that can hold a static load at least ten times heavier than the total weight they must secure and are approved for this weight by a technical standards organization such as T V Warning Mainta...

Page 8: ...ED system 1 Check that the pipe or truss onto which you are mounting the EvenLED system is horizontal 2 See Figure 2 Loosen the clamp position locking rings 3 and slide the clamps 1 as wide apart as p...

Page 9: ...ough the top handle 14 of the frame 9 Connect DMX and power cables Adding panels vertically To add panels underneath the first panel 1 See Figure 3 on page 9 Loosen the panel to panel locking knob 9 a...

Page 10: ...s 1 to 4 above Check that all safety wires are attached exactly as shown in Figure 6 and described above Adding panels horizontally To add a panel beside a panel that is already installed 1 Suspend th...

Page 11: ...ond to commands it receives on channels starting at channel 1 the DMX signal at the first panel s DMX OUT output is processed by subtracting 96 channels and re addressing the commands sent from the co...

Page 12: ...on page 11 and see examples in Figure 8 Do not connect more than 32 devices in one chain on a DMX512 link without using a splitter amplifier Do not split a DMX link with a passive Y connector Branchi...

Page 13: ...t limitations Refer to AC power on page 15 for details of establishing power circuits Figure 8 System layouts A Individual control Panels respond to different commands sent to different DMX addresses...

Page 14: ...el but use this output for grouped DMX control of panels in which panels share the same DMX address respond to the same DMX commands and behave identically Power connectors The blue Neutrik PowerCon P...

Page 15: ...t accidental reconnection during service and each power distribution circuit must be dimensioned to safely handle a current of 20 A for each chain of EvenLED panels connected to it Important Do not co...

Page 16: ...t the yellow green wire to ground earth Connect the blue wire to neutral Connect the brown wire to live 4 Check that all installation work is completed and carry out appropriate tests and safety check...

Page 17: ...If a panel shuts down although it is correctly connected to power this circuit may have been activated by a fault Disconnect the panel from power and contact your Martin supplier for assistance If the...

Page 18: ...See System layouts on page 13 for diagrams of possible installations To connect a panel to the data link 1 Connect the DMX data output from the controller to the EvenLED s DMX IN male XLR socket 2 Ru...

Page 19: ...sing a standard DMX 512 controller 16 and 8 bit DMX control modes The EvenLED panel is designed to be used with 16 bit control per color This ensure smooth and step free operation and requires 96 DMX...

Page 20: ...ottom two rows simply repeat the number displayed on the top two rows Software version display example See Figure 14 If a panel is running software version 29 20 LED 15 lights in the top row 1 and 8 L...

Page 21: ...on Step 1 and while you check panel mode settings Step 9 but steps 2 to 8 must change to the next step at 1 second intervals You only change DMX values for the red LEDs in each step The green and blue...

Page 22: ...tep 5 During steps 6 to 8 panels indicate which mode settings they are acquiring by lighting LEDs red or green as shown in Figure 15 on page 21 If you send an Ignore value for a mode setting that you...

Page 23: ...lue Hex value Setting Panel configuration enable Step 1 Reds1 20 46 56 Hold this value at power on Greens and blues2 50 122 132 Hold this value at power on and throughout the rest of the procedure Sta...

Page 24: ...ou may eventually need to ask Martin Professional to replace LEDs if their characteristics are affected by wear and tear after an extended period of use and if you require panels to perform within ver...

Page 25: ...orrect use of DMX OUT and DMX THROUGH connectors Check number of channels required by panels in one chain does not exceed 512 if individual control is required Incorrect mode setting Check panels are...

Page 26: ...mm 9 8 in Pixels per m2 16 Color resolution 16 bits per color Viewing angle 112 56 56 Minimum LED source lifetime to 70 of initial output level 40 000 hours at full intensity C o ns t ru c tio n Pane...

Page 27: ...power input cable with PowerCon input connector P N 11541503 User manual P N 35000222 A cc e ss o r ies Neutrik PowerCon NAC3FCA power input connector cable mount blue P N 05342804 Neutrik PowerCon NA...

Page 28: ...an Parliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Reviews: