13
91401 4 04/13
45SC2 45CC3 45CC4 45CC5 45CC6 60SC2 60CC3 60CC4 60CC5 60CC6
MALFUNCTIONS
MAINTENANCE / DISPOSING
TECHNICAL DATA
SPECIAL ACCESSORIES
GB
fig. 5
fig. 6
Translation of the Original Operation Manual
Übersetzung der Originalbetriebsanleitung
7
Description
Order-No.
Plastic bag, 440x330x600x0.05 mm (45)
83079
Plastic bag, 440x330x950x0.05 mm (60)
99977
Lubricant, 110 ml bottle
88035
Note:
For orders of special accessories and spare parts,
please contact your dealer.
CUTTER MAINTENANCE (CROSS CUT):
Cross cut cutters must be oiled after a
specific operating time. If the control
display (7) comes on proceed as
follows:
Open the door. The control display (8) comes
on and the reverse button (4) LED display
as well as the control display (7)
flashes
.
Remove the oil reservoir (13) (Fig. 6) from the
holder in the door and close the door again.
Pour a little oil onto a sheet of paper and then
feed this through the paper feed slot (11) onto
the cutters.
The paper is drawn in and in this way the oil is
distributed to the cutters.
Note: This procedure is acknowledged as
follows to turn off the display after the cutters
have been oiled:
- Open the door until the control display (8)
lights up. The control displays (7) and (4)
flash.
- Press the reverse button (4) and keep it
held down until the control display (7) goes
out.
CLEANING THE PHOTOCELLS (Fig. 5):
If paper particles should come to rest in the
inlet guide (for example after a paper jam) it is
possible that the machine will not turn off, due to
the broken light barrier.
To remove these paper strips and also to clean
the photocell, pass another sheet of paper
through the feed slot, or switch the machine to
reverse and wipe both “eyes” of the photocell
with a brush.
- Close the door again.
The cutters now start a cleaning cycle
automatically (forward and reverse run) and then
switch off. The machine is ready for use again.
Should you need to re-order the special oil see
“SPECIAL ACCESSORIES”.
AUTOMATIC ENERGY SAVING:
If the machine is not used for a while it
automatically switches off after about 5 minutes.
The function button (2) LED display for
“Ready” goes out. Press the function button
briefly to turn it on again.
DISPOSING OF THE MACHINE:
Dispose of the machine in an
environmentally friendly fashion at the
end of its useful service life. Do not
dispose of any of the parts included
in the machine or its packaging with
household waste.
MATERIAL JAM IN THE MACHINE:
(Auto reverse function)
If a jam is caused by too much material being fed
in the following happens:
- The cutters jam, then run in reverse for a short
time (material is released) and stop. The motor
switches off. The control display (6) comes
on.
Proceed as follows:
Paper jam in paper feed slot (11)
- Remove the paper that has been fed back.
- The cutters now run forwards automatically
and shred the remaining paper in the cutters.
During the forward run the forward button (3)
LED display comes on. The control display
(6) goes out.
- Continue shredding with less paper.
- If necessary, switch the cutters manually
alternately from forward to reverse until the
material has gone through completely and
been shredded.
LIGHT BARRIER COVERED
WHEN DOOR OPENED:
Should there still be material in the feed slot
when the door is opened, the motor switches off
and the cutters stop. The control display (6)
comes on.
Close the door and acknowledge the status
by pressing the forward button (3) briefly.
The existing material is fed to the cutters and
shredded.
LIGHT BARRIER COVERED
WHEN MACHINE TURNED ON:
Should there still be material in the feed slot
when the machine is switched on the control
display (6) comes on.
Remove the material and acknowledge the
status by pressing the forward button (3) briefly.
MOTOR PROTECTION:
Should the motor be overloaded it switches off.
The control display (9) comes on.
The machine can be started again after a cooling
down period of about 25 – 40 minutes.
ELECTRICAL FAULT:
If the control display (9)
flashes
together with
the function button (2) LED display or only
the control display (8)
flashes
there is an
electrical fault. The machine cannot be started.
In this case please contact your dealer.
FAULT CHECK LIST:
Should the machine not work, check the following
points:
- is the
plug
connected to the power supply?
- is the
door
closed?
- is the
paper collection bag
full?
Follow the instructions for “EMPTYING THE
PAPER COLLECTION BAG“.
- Is there a
material jam
in the machine?
Follow the instructions in “MATERIAL JAM IN
THE MACHINE”.
- Is the
motor
overloaded?
See “MOTOR PROTECTION”.
If none of these test points apply, please
contact your dealer.
* based on A4-paper 70g/m² at 230V/50Hz
Model
Type
Cutting width
Cutting capacity
Working width Noise level
Dimensions
Weight
paper
paper
W x D x H
intimus 45SC2
278-4S
3.8 mm
22-24 sheets*
235 mm
app. 55 dB(A)
450 x 390 x 650 mm
31 kg
intimus 45CC3
278-4C
3.8x30 mm
13-15 sheets*
235 mm
app. 55 dB(A)
450 x 390 x 650 mm
32 kg
intimus 45CC4
278-2C
1.9x15 mm
10-11 sheets*
235 mm
app. 55 dB(A)
450 x 390 x 650 mm
32 kg
intimus 45CC5
278-1C
0.8x12 mm
5-6 sheets*
235 mm
app. 55 dB(A)
450 x 390 x 650 mm
32 kg
intimus 45CC6
278-1CF
0.8x4.5 mm
5-6 sheets*
235 mm
app. 55 dB(A)
450 x 390 x 650 mm
32 kg
intimus 60SC2
279-4S
3.8 mm
22-24 sheets*
235 mm
app. 55 dB(A)
450 x 390 x 770 mm
33 kg
intimus 60CC3
279-4C
3.8x30 mm
13-15 sheets*
235 mm
app. 55 dB(A)
450 x 390 x 770 mm
34 kg
intimus 60CC4
279-2C
1.9x15 mm
10-11 sheets*
235 mm
app. 55 dB(A)
450 x 390 x 770 mm
34 kg
intimus 60CC5
279-1C
0.8x12 mm
5-6 sheets*
235 mm
app. 55 dB(A)
450 x 390 x 770 mm
34 kg
intimus 60CC6
279-1CF
0.8x4.5 mm
5-6 sheets*
235 mm
app. 55 dB(A)
450 x 390 x 770 mm
34 kg
Model
Power supply data
supply voltage/frequency · current consumption · power
intimus 45/60SC2
220-230V/50Hz · 3,0
amps
· 0,7 kW
120V/60Hz · 5,6
amps
· 0,7 kW
100V/50/60Hz · 7,0
amps
· 0,7 kW
intimus 45/60CC3+CC4+CC5
220-230V/50Hz · 3,0
amps
· 0,55 kW
120V/60Hz · 5,6
amps
· 0,55 kW
100V/50/60Hz · 7,0
amps
· 0,55 kW
intimus 45/60CC6
220-230V/50Hz · 3,0
amps
· 0,7 kW
120V/60Hz · 5,6
amps
· 0,7 kW
100V/50/60Hz · 7,0
amps
· 0,7 kW
Pre-fusing
(slow-blow)
:
220-230V = 10 amps / 120V = 15 amps / 100V = 15 amps