XE300/XE500
User Guide V1.0
33
XE300/XE500
USER GUIDE
Power Output iK42
Power specification
RMS output power per channel, all channels driven with continuous program
material and a nominal ambient temperature of 40 degC / 105 degF
Crest Factor of 4 (12 dB), 2 ohm nominal load
5,000 W
Crest Factor of 2.8 (9 dB), 4 ohm nominal load
3,000 W
Crest Factor of 2 (6 dB), 8 ohm nominal load
1,500 W
Bridged, per channel pair, 4 ohm load
10,000 W
25 V line (CV) operation, Crest Factor 4 (12 dB)
1,250 W
70 V line (CV) operation, Crest Factor 4 (12 dB)
3,500 W
100 V line (CV) operation, Crest Factor 4 (12 dB) 5,000 W
Power Output iK81
Power specification
RMS output power per channel, all channels driven with continuous program
material and a nominal ambient temperature of 40 degC / 105 degF
Crest Factor of 4 (12dB ), 2-Ohm nominal load
1,250 W
Crest Factor of 2.8 (9dB), 4-Ohm nominal load
1,250 W
Crest Factor of 2 (6dB), 8-Ohm nominal load
1,250 W
Bridged, per channel pair, 4 Ohm load
2,500 W
25 V line (CV) operation, Crest Factor 4 (12dB)
625 W
70 V line (CV) operation, Crest Factor 4 (12dB)
1,250 W
100 V line (CV) operation, Crest Factor 4 (12dB)
1,250 W
Power supply
Topology (main power supply)
3rd generation Series Resonant
Topology (auxiliary and standby supplies)
Low quiescent Eco-Flyback
Internally stored energy
>600 Joules
Mains input voltage range (automatically
configured)
85 V to 240 V
Mains input frequency range
47 Hz to 63 Hz
Mains inrush current (max for <10 ms)
6 A at 115 V, 12 A at 230 V
Protection systems
Note: Under all circumstances the control and protection systems will endeavour to deliver the maximum power possible for a given
set of conditions, applying limiters only in extreme circumstances. Muting will only occur when a dangerous situation is detected,
normal operation automatically resuming when the condition clears.
System protection
Speaker protection
Excessive output current
Audio soft-clip limiter
Excessive power supply current
VxLim, Multiband peak limiter
Excessive amplifier section temperature
VxMax, Multiband overshoot limiter
Excessive power supply section temperature
Vx-Xmax, Driver excursion limiter
Excessive DSP section temperature
Vx-Tmax, Driver thermal limiter (long term power limiter)
Mains voltage out of range
DC offset protection
Fan speeds out of range
Excessive HF energy (VHF) limiter
Internal power rails out of range
Power distribution protection systems
Mains inrush current limiting (soft start and anti-surge)
Mains average current limiting (mains breaker / fuse trip protection)
Randomised initialisation when powered up to reduce the peak power demand in large systems
Summary of Contents for XE300
Page 1: ...MARTIN AUDIO XE SERIES XE300 XE500 USER GUIDE...
Page 25: ...XE300 XE500 User Guide V1 0 25 XE300 XE500 USER GUIDE Processing Block Diagram...
Page 26: ...XE300 XE500 User Guide V1 0 26 XE300 XE500 USER GUIDE Input Menu Map...
Page 27: ...XE300 XE500 User Guide V1 0 27 XE300 XE500 USER GUIDE Output Menu Map...
Page 28: ...XE300 XE500 User Guide V1 0 28 XE300 XE500 USER GUIDE Utility Menu Map...
Page 37: ...XE300 XE500 User Guide V1 0 37 XE300 XE500 USER GUIDE...