Copyright © 2021 Martin Audio Ltd.
79
SX SERIES USER GUIDE V2.5
SX SERIES USER GUIDE
SXP118
Wiring Instructions
Wiring instructions for the Neutrik PowerCon True1 are as follows. Note that all mains wiring should be carried out by a competent, trained
technician. If a suitable technician is not available Martin Audio would recommend purchasing one of the range of pre-made mains
cables available as optional accessories. These feature the PowerCon True1 connector on a flexible cable of either 2.15m (part number
ASF12024) or 5m (part number ASF12023) in length and are terminated in a 16A male Ceeform connector. Both cables are rated to IP67.
Approval based:
VDE
EN 60320
UL
UL 498 / C22.2 No. 182.3
Rating:
250 V ac / 16A
250 V ac / 20 A
Cable Type:
H05VV-F3G 1.0mm², Length max. 2m
H05VV-F3G 1.5 – 2.5mm²
H07RN-F3G 1.5mm²
SJTOW, SJOOW 3 x 12 AWG
Strain Relief:
White Chuck
White Chuck
Cable O.D.:
6.0 – 12.0 mm
6.0 – 12.0 mm
A: Prepare cable as shown.
B: Place chuck over cable.
C: Wire the connector
Using a Torx T8 driver, the fixing screws
should be tightened to a torque value of
0.7Nm.
Live
Neutral
Ground
Brown
Blue
Green/yellow
Black
White
Green